A code on the display?

20 fault codes for the FJ 7 PLUS ROOFTOP, from Dometic's own documents. Tap one to see what to check.

ADB 8 fast + 8 slow beeps13-pin connector not seated

Likely cause: The 13-pin plug is loose at the main PCB or the transfer PCB.

Dometic's checks, in order: Check and reseat the plug at both ends and inspect for damaged pins.

Source: Freshjet 4 & 7 series Error codes, page 1. Open the document

E0Communication failure

Likely cause: Lost communication between display and main boards, or loss of outdoor power supply.

Dometic's checks, in order: Check the communication cable at both PCBs and repair if loose/damaged; test with a spare display PCB; if still faulty replace the main PCB.

Source: Freshjet 4 & 7 series Error codes, page 1. Open the document

E1Room temperature sensor fault

Likely cause: Indoor ambient sensor open or short circuit.

Dometic's checks, in order: Check the room-sensor reading via the ADB; replace the sensor if abnormal.

Source: Freshjet 4 & 7 series Error codes, page 1. Open the document

E2Evaporator coil sensor fault

Likely cause: Indoor coil sensor open or short circuit.

Dometic's checks, in order: Check the coil-sensor reading via the ADB; replace the sensor if abnormal.

Source: Freshjet 4 & 7 series Error codes, page 1. Open the document

E3Condenser coil sensor fault

Likely cause: Outdoor coil sensor open or short circuit.

Dometic's checks, in order: Check the coil-sensor reading via the ADB; replace the sensor if abnormal.

Source: Freshjet 4 & 7 series Error codes, page 1. Open the document

EACurrent sensor fault

Likely cause: The system detected no current.

Dometic's checks, in order: If shown immediately at switch-on it is a hardware fault: replace the main PCB. If shown after the compressor starts (very low compressor current for over 30 s at 35 Hz or more), check refrigerant charge and repair leaks.

Source: Freshjet 4 & 7 series Error codes, page 1. Open the document

Show all 20 codes

ECNot documented

Likely cause: Sheet gives no cause.

Dometic's checks, in order: Contact Dometic.

Source: Freshjet 4 & 7 series Error codes, page 1. Open the document

EEOutdoor EEPROM fault

Likely cause: Main board cannot read its EEPROM data.

Dometic's checks, in order: Replace the main PCB.

Source: Freshjet 4 & 7 series Error codes, page 1. Open the document

EHNot documented

Likely cause: Sheet gives no cause.

Dometic's checks, in order: Contact Dometic.

Source: Freshjet 4 & 7 series Error codes, page 1. Open the document

ELLIN-BUS / CI-BUS communication failure

Likely cause: Bus communication failed during the start-up self-check.

Dometic's checks, in order: Check the LIN/CI-BUS cable and connections and the RV's master control panel; if the fault persists replace the display PCB.

Source: Freshjet 4 & 7 series Error codes, page 1. Open the document

EPNot documented

Likely cause: Sheet gives no cause.

Dometic's checks, in order: Contact Dometic.

Source: Freshjet 4 & 7 series Error codes, page 1. Open the document

EUNot documented

Likely cause: Sheet gives no cause.

Dometic's checks, in order: Contact Dometic.

Source: Freshjet 4 & 7 series Error codes, page 1. Open the document

P1Supply voltage too low (under-voltage protection)

Likely cause: Mains input has dropped below about 130 V (+/-5 V).

Dometic's checks, in order: Check the 240 V supply reaching the unit (lead, site power or generator).

Source: Freshjet 4 & 7 series Error codes, page 1. Open the document

P2AC over-current protection

Likely cause: Running current is above the unit's limit.

Dometic's checks, in order: Check supply voltage, confirm both fan motors run, measure compressor current; replace the compressor if its draw is abnormal, otherwise the main PCB.

Source: Freshjet 4 & 7 series Error codes, page 1. Open the document

P3Supply voltage problem (not in the main table)

Likely cause: Unstable or unsuitable supply, commonly a generator that is undersized or not pure sine wave.

Dometic's checks, in order: Check the generator size and quality (pure sine wave, inverter-compatible).

Source: Freshjet 4 & 7 series Error codes, page 1. Open the document

P4Compressor discharge pipe too hot

Likely cause: Discharge-tube temperature is over the protection limit.

Dometic's checks, in order: Read the discharge temperature through the ADB; replace the sensor if the reading is wrong, otherwise check coil temperatures and refrigerant charge (leak-test and recharge if low).

Source: Freshjet 4 & 7 series Error codes, page 1. Open the document

P5Evaporator coil too cold (cooling mode)

Likely cause: Indoor coil temperature has fallen too low while cooling. On early Freshjet ADBs (built before week 40/2023, ADB serial below 340xxxxx) a faulty display PCB can also throw a spurious P5 and change settings by itself (Dometic bulletin 130324).

Dometic's checks, in order: Check the indoor fan runs and read the coil sensor through the ADB; replace the sensor if wrong, otherwise check refrigerant charge. If the early-ADB symptoms match, the fix is replacement display PCB 4450031469 (bulletin 130324).

Source: Freshjet 4 & 7 series Error codes, page 1. Open the document

P6Condenser coil too hot (cooling mode)

Likely cause: Outdoor coil temperature is too high while cooling.

Dometic's checks, in order: Clear any blockage at the condenser air inlet/outlet, check the condenser fan, read the coil sensor through the ADB; replace the sensor if wrong, otherwise check refrigerant charge.

Source: Freshjet 4 & 7 series Error codes, page 1. Open the document

P7Evaporator coil too hot (heating mode)

Likely cause: Indoor coil temperature is too high while heating.

Dometic's checks, in order: Check the indoor fan and the coil sensor reading through the ADB; replace the sensor if wrong, otherwise check refrigerant charge.

Source: Freshjet 4 & 7 series Error codes, page 1. Open the document

P8Outdoor temperature out of range

Likely cause: Outside air below 0 C in cooling mode, or above 32 C in heating mode.

Dometic's checks, in order: Confirm the right mode was selected; check the outdoor sensor is mounted where it belongs (not touching the compressor or hot pipework) and reads correctly via the ADB; if all OK replace the main PCB.

Source: Freshjet 4 & 7 series Error codes, page 1. Open the document

Documents for the FJ 7 PLUS ROOFTOP2 documents from Dometic
  • FJ 7 PLUS ROOFTOP spare parts listParts list · released 10 Nov 2022
  • Freshjet 4 & 7 series Error codesTroubleshooting guide · released Jun 2024 · Open it
Where these numbers come from

We don't invent part numbers. Every number on this page is copied from Dometic's documents listed above, with the page. If a document is in doubt we hold the part back and say so.

How we check a part fits

Not sure it's an FJ 7 PLUS ROOFTOP?

On a roof-top air conditioner it's on the ceiling unit inside: take off the return-air grille or lift out the filter and look up. Otherwise it's on the roof unit under the shroud.

How to read the plate All Dometic models

All 11 parts for the FJ 7 PLUS ROOFTOP

Every part Dometic's documents list for the FJ 7 PLUS ROOFTOP, grouped by area. Tap a part for its price, where to buy it and the page it came from.

Prices last seen between 16 Sep 2026 and 27 Oct 2026. Each price shows its own date. The shop's own page is final.

Seals & doors1 part
Electrical5 parts
  • Fan evaporator fj4

    Part no. 4450030739Fits your FJ 7 PLUS ROOFTOP

    Callout 2 · FJ 7 PLUS ROOFTOP spare parts list, page 2

    None in stock 2 shops list it · last seen 27 Oct

    Compare 2 shops
  • Pcb main fj7 plus

    Part no. 4450032950Fits your FJ 7 PLUS ROOFTOP

    Callout 3 · FJ 7 PLUS ROOFTOP spare parts list, page 2

    None in stock 2 shops list it · last seen 27 Oct

    Compare 2 shops
  • Fan condenser fj7

    Part no. 4450032946Fits your FJ 7 PLUS ROOFTOP

    Callout 5 · FJ 7 PLUS ROOFTOP spare parts list, page 2

    None in stock 2 shops list it · last seen 27 Oct

    Compare 2 shops
  • Motor fan evaporator fj7

    Part no. 4450032948Fits your FJ 7 PLUS ROOFTOP

    Callout 8 · FJ 7 PLUS ROOFTOP spare parts list, page 2

    None in stock 2 shops list it · last seen 27 Oct

    Compare 2 shops
  • Sensor set fj7

    Part no. 4450032949Fits your FJ 7 PLUS ROOFTOP

    Callout 11 · FJ 7 PLUS ROOFTOP spare parts list, page 2

    None in stock 2 shops list it · last seen 27 Oct

    Compare 2 shops
Other parts5 parts
  • Compressor fj7

    Part no. 4450032942Fits your FJ 7 PLUS ROOFTOP

    Callout 1 · FJ 7 PLUS ROOFTOP spare parts list, page 2

    None in stock 2 shops list it · last seen 27 Oct

    Compare 2 shops
  • Condenser fj7 plus

    Part no. 4450032984Fits your FJ 7 PLUS ROOFTOP

    Callout 4 · FJ 7 PLUS ROOFTOP spare parts list, page 2

    None in stock 2 shops list it · last seen 27 Oct

    Compare 2 shops
  • Shroud fj7 plus

    Part no. 4450030866Fits your FJ 7 PLUS ROOFTOP

    Callout 6 · FJ 7 PLUS ROOFTOP spare parts list, page 2

    None in stock 1 shop lists it · last seen 27 Oct

    Where to buy
  • Evaporator fj7 plus

    Part no. 4450032985Fits your FJ 7 PLUS ROOFTOP

    Callout 7 · FJ 7 PLUS ROOFTOP spare parts list, page 2

    None in stock 2 shops list it · last seen 27 Oct

    Compare 2 shops
  • Capacitor 5uf fj7

    Part no. 4450024065Fits your FJ 7 PLUS ROOFTOP

    Callout 10 · FJ 7 PLUS ROOFTOP spare parts list, page 2

    None in stock 2 shops list it · last seen 27 Oct

    Compare 2 shops
What the fit words mean
  • Fits 11 parts. Dometic's own list for the FJ 7 PLUS ROOFTOP names this exact number, and a second check agreed.

Parts shared across a range are often named after the first model they were made for, so a name may mention a different model. That doesn't mean it won't fit yours.

Is this my air conditioner?

Check the plate on your air conditioner says FJ 7 PLUS ROOFTOP.

MOD. NO.
FJ 7 PLUS ROOFTOP
Item or product code
9620001689

On a roof-top air conditioner it's on the ceiling unit inside: take off the return-air grille or lift out the filter and look up. Otherwise it's on the roof unit under the shroud.

Where's the plate on a Dometic air conditioner?

Not your model? See all Dometic models or ask us to find it.

Yes, show my parts