Dometic fridge
Dometic CFX3 portable fridge warning and alert codes
All 12 codes, what each one means and what to check, from Dometic CFX3 25/35/45/55/55IM/75DZ/95DZ operating manual APAC (EN).
!ALERT - Lid open > 3minLid has been open more than 3 minutes.
Likely cause: Lid not fully latched, or internal fault.
Dometic's checks, in order: Check the lid is latched; if it persists, have it inspected by a repair centre.
Source: Dometic CFX3 25/35/45/55/55IM/75DZ/95DZ operating manual APAC (EN), page 36. Open the PDF
!ALERT - Voltage lowCooler stopped on DC because supply voltage is too low (or above 31.5 V).
Likely cause: Voltage drop in wiring, low battery, battery protection set too high, or wrong supply.
Dometic's checks, in order: Check voltage drop and cable size, charge battery, lower battery protection setting.
Source: Dometic CFX3 25/35/45/55/55IM/75DZ/95DZ operating manual APAC (EN), page 36. Open the PDF
!WARNING 32Fan over-current.
Likely cause: Internal fault in the condenser fan circuit.
Dometic's checks, in order: Turn off at least 5 minutes and restart; if it persists, repair centre inspection.
Parts these checks can point to
Source: Dometic CFX3 25/35/45/55/55IM/75DZ/95DZ operating manual APAC (EN), page 37. Open the PDF
!WARNING 33Compressor failed to start.
Likely cause: Internal fault (compressor or control electronics).
Dometic's checks, in order: Turn off at least 5 minutes and restart; if it persists, repair centre inspection.
Parts these checks can point to
Source: Dometic CFX3 25/35/45/55/55IM/75DZ/95DZ operating manual APAC (EN), page 37. Open the PDF
!WARNING 34Compressor speed too low.
Likely cause: High ambient temperature, blocked vents or poor clearance, or internal fault.
Dometic's checks, in order: Turn off 30 minutes or move somewhere cooler, clear vents, then restart.
Parts these checks can point to
Source: Dometic CFX3 25/35/45/55/55IM/75DZ/95DZ operating manual APAC (EN), page 37. Open the PDF
!WARNING 35Controller over-temperature.
Likely cause: High ambient, blocked vents or poor clearance, or internal fault.
Dometic's checks, in order: Turn off 30 minutes or move somewhere cooler, clear vents, then restart.
Parts these checks can point to
Source: Dometic CFX3 25/35/45/55/55IM/75DZ/95DZ operating manual APAC (EN), page 37. Open the PDF
!WARNING 01Temperature sensor (NTC) open circuit - single zone or large DZ compartment.
Likely cause: Sensor or wiring failed (internal fault).
Dometic's checks, in order: Authorised repair centre inspection required.
Parts these checks can point to
Source: Dometic CFX3 25/35/45/55/55IM/75DZ/95DZ operating manual APAC (EN), page 37. Open the PDF
!WARNING 02Temperature sensor (NTC) short circuit - single zone or large DZ compartment.
Likely cause: Sensor or wiring failed (internal fault).
Dometic's checks, in order: Authorised repair centre inspection required.
Parts these checks can point to
Source: Dometic CFX3 25/35/45/55/55IM/75DZ/95DZ operating manual APAC (EN), page 37. Open the PDF
!WARNING 11Temperature sensor (NTC) open circuit - small dual-zone compartment.
Likely cause: Sensor or wiring failed (internal fault).
Dometic's checks, in order: Authorised repair centre inspection required.
Parts these checks can point to
Source: Dometic CFX3 25/35/45/55/55IM/75DZ/95DZ operating manual APAC (EN), page 37. Open the PDF
!WARNING 12Temperature sensor (NTC) short circuit - small dual-zone compartment.
Likely cause: Sensor or wiring failed (internal fault).
Dometic's checks, in order: Authorised repair centre inspection required.
Parts these checks can point to
Source: Dometic CFX3 25/35/45/55/55IM/75DZ/95DZ operating manual APAC (EN), page 37. Open the PDF
!WARNING 09Dual-zone valve or ice-maker valve faulty.
Likely cause: Valve or its wiring failed.
Dometic's checks, in order: Turn off at least 1 minute and restart; if it persists, repair centre inspection.
Source: Dometic CFX3 25/35/45/55/55IM/75DZ/95DZ operating manual APAC (EN), page 37. Open the PDF
!WARNING 03/43Internal communication error.
Likely cause: Fault between display and control electronics.
Dometic's checks, in order: Turn off at least 1 minute and restart; if it persists, repair centre inspection.
Parts these checks can point to
Source: Dometic CFX3 25/35/45/55/55IM/75DZ/95DZ operating manual APAC (EN), page 37. Open the PDF
Where this comes from
Dometic CFX3 25/35/45/55/55IM/75DZ/95DZ operating manual APAC (EN), published by Dometic. Open the PDF
We don't invent fault codes or part numbers. Each code above carries the page it came from.