SparePartsMatcher

Dometic air conditioner

Dometic RTX2000 parking cooler F error codes

All 20 codes, what each one means and what to check, from Dometic RTX2000, SPX1200IC parking cooler operating manual APAC (EN).

F01Compressor not working: compressor sensor supply open circuit.

Source: Dometic RTX2000, SPX1200IC parking cooler operating manual APAC (EN). Open the PDF

F02Compressor not working: compressor sensor supply short circuit.

Source: Dometic RTX2000, SPX1200IC parking cooler operating manual APAC (EN). Open the PDF

F03Compressor overload.

Source: Dometic RTX2000, SPX1200IC parking cooler operating manual APAC (EN). Open the PDF

F04Condenser fan 1 not working.

Source: Dometic RTX2000, SPX1200IC parking cooler operating manual APAC (EN). Open the PDF

F05Condenser fan 1 overloaded.

Source: Dometic RTX2000, SPX1200IC parking cooler operating manual APAC (EN). Open the PDF

F06Condenser fan 2 not working.

Source: Dometic RTX2000, SPX1200IC parking cooler operating manual APAC (EN). Open the PDF

F07Condenser fan 2 overloaded.

Source: Dometic RTX2000, SPX1200IC parking cooler operating manual APAC (EN). Open the PDF

F08Evaporator fan not working.

Source: Dometic RTX2000, SPX1200IC parking cooler operating manual APAC (EN). Open the PDF

F09Evaporator fan overloaded.

Source: Dometic RTX2000, SPX1200IC parking cooler operating manual APAC (EN). Open the PDF

F10Condensation water is not draining.

Source: Dometic RTX2000, SPX1200IC parking cooler operating manual APAC (EN). Open the PDF

F11Cannot read internal temperature: sensor open circuit.

Source: Dometic RTX2000, SPX1200IC parking cooler operating manual APAC (EN). Open the PDF

F12Cannot read internal temperature: sensor short circuit.

Source: Dometic RTX2000, SPX1200IC parking cooler operating manual APAC (EN). Open the PDF

F13Cannot read external temperature: sensor open circuit.

Source: Dometic RTX2000, SPX1200IC parking cooler operating manual APAC (EN). Open the PDF

F14Cannot read external temperature: sensor short circuit.

Source: Dometic RTX2000, SPX1200IC parking cooler operating manual APAC (EN). Open the PDF

F15Cannot read compressor temperature: sensor open circuit.

Source: Dometic RTX2000, SPX1200IC parking cooler operating manual APAC (EN). Open the PDF

F16Cannot read compressor temperature: sensor short circuit.

Source: Dometic RTX2000, SPX1200IC parking cooler operating manual APAC (EN). Open the PDF

F17Compressor temperature too high.

Source: Dometic RTX2000, SPX1200IC parking cooler operating manual APAC (EN). Open the PDF

F20Temporary electrical overload.

Source: Dometic RTX2000, SPX1200IC parking cooler operating manual APAC (EN). Open the PDF

F21Control PCB not working.

Source: Dometic RTX2000, SPX1200IC parking cooler operating manual APAC (EN). Open the PDF

F22Display board not working.

Source: Dometic RTX2000, SPX1200IC parking cooler operating manual APAC (EN). Open the PDF

Where this comes from

Dometic RTX2000, SPX1200IC parking cooler operating manual APAC (EN), published by Dometic. Open the PDF

We don't invent fault codes or part numbers. Each code above carries the page it came from.