Dometic fridge
Dometic RUA 3-way fridge error codes (RUA5208X, RUA6408X, RUA8408X)
All 23 codes, what each one means and what to check, from Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN).
01Thermostat (temperature) sensor error; fridge cycles 45 min on, 15 min off.
Likely cause: Failed or disconnected temperature sensor.
Dometic's checks, in order: Contact an authorised Dometic service agent.
Parts these checks can point to
Source: Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN), page 43. Open the PDF
05AC power not connected or mains below 190 V.
Likely cause: No mains supply or low mains voltage.
Dometic's checks, in order: Connect to AC power or choose gas or DC.
Source: Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN), page 43. Open the PDF
06DC power supply not connected.
Likely cause: No 12 V reaching the fridge.
Dometic's checks, in order: Connect DC power or choose gas or AC.
Source: Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN), page 43. Open the PDF
10Door has been open for more than 2 minutes.
Likely cause: Door left open or not latched; door sensor fault.
Dometic's checks, in order: Close the refrigerator door.
Parts these checks can point to
Source: Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN), page 43. Open the PDF
11DC overvoltage (above 16 V).
Likely cause: Charger, alternator or solar regulator supplying too high a voltage.
Dometic's checks, in order: Reduce the DC supply voltage.
Source: Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN), page 43. Open the PDF
14Internal fan defective; cooling continues on a fixed setting.
Likely cause: Failed interior fan or its wiring.
Dometic's checks, in order: Contact an authorised Dometic service agent.
Parts these checks can point to
Source: Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN), page 43. Open the PDF
15Low current at the frame heater.
Likely cause: Frame heater or its wiring faulty.
Dometic's checks, in order: Switch off and on; contact a service agent if it returns.
Source: Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN), page 43. Open the PDF
17Low current at the defrost heater.
Likely cause: Defrost heater or its wiring faulty.
Dometic's checks, in order: Switch off and on; contact a service agent if it returns.
Parts these checks can point to
Source: Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN), page 43. Open the PDF
22GASDC undervoltage (below 10 V); fridge switches to gas.
Likely cause: Flat or weak vehicle battery.
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Dometic's checks, in order: Charge the vehicle battery.
Source: Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN), page 43. Open the PDF
24Display has a poor ground (earth) connection.
Likely cause: Bad negative/earth connection to the display.
Dometic's checks, in order: Ensure good grounding; contact a service agent if it returns.
Source: Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN), page 43. Open the PDF
Tank stopGASGas operation blocked for 15 minutes (refuelling mode).
Likely cause: Tank stop mode was activated.
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Dometic's checks, in order: Wait 15 minutes or select another energy source.
Source: Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN), page 43. Open the PDF
03No communication between power module and display; runs on last settings.
Likely cause: Display or power module fault, or cable between them.
Dometic's checks, in order: Contact an authorised Dometic service agent.
Parts these checks can point to
Source: Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN), page 44. Open the PDF
07GASNo cooling capacity on gas.
Likely cause: Fridge not level, or gas-side fault.
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Dometic's checks, in order: Level the vehicle, reset the error; call service if it returns.
Parts these checks can point to
Source: Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN), page 44. Open the PDF
08No cooling capacity on AC (mains).
Likely cause: Fridge not level, or AC heater fault.
Dometic's checks, in order: Level the vehicle, reset the error; call service if it returns.
Parts these checks can point to
Source: Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN), page 44. Open the PDF
09No cooling capacity on DC (12 V).
Likely cause: Fridge not level, or DC heater fault.
Dometic's checks, in order: Level the vehicle, reset the error; call service if it returns.
Parts these checks can point to
Source: Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN), page 44. Open the PDF
12GASGas valve test failed; gas operation locked.
Likely cause: Gas valve or its circuit faulty.
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Dometic's checks, in order: Reset the error; contact a service agent if it returns.
Parts these checks can point to
Source: Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN), page 44. Open the PDF
13GASFaulty dynamic valve signal; gas operation locked.
Likely cause: Gas valve control signal fault.
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Dometic's checks, in order: Reset the error; contact a service agent if it returns.
Parts these checks can point to
Source: Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN), page 44. Open the PDF
16Frame heater over-current; heater switched off.
Likely cause: Short or fault in the frame heater circuit.
Dometic's checks, in order: Reset the error; contact a service agent if it returns.
Source: Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN), page 44. Open the PDF
18Defrost heater over-current; heater switched off.
Likely cause: Short or fault in the defrost heater circuit.
Dometic's checks, in order: Reset the error; contact a service agent if it returns.
Parts these checks can point to
Source: Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN), page 44. Open the PDF
50GASGas locked out after 3 failed ignition attempts.
Likely cause: Gas cylinder empty or turned off.
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Dometic's checks, in order: Replace or turn on the gas cylinder, then reset the error.
Source: Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN), page 44. Open the PDF
51GASGas lock; gas operation locked.
Likely cause: Gas system fault detected.
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Dometic's checks, in order: Reset the error; contact a service agent if it returns.
Source: Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN), page 44. Open the PDF
52GASShort circuit in gas valve; gas locked.
Likely cause: Gas valve coil or wiring shorted.
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Dometic's checks, in order: Reset the error; contact a service agent if it returns.
Parts these checks can point to
Source: Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN), page 44. Open the PDF
53GASShort circuit of ignition electrode; gas locked.
Likely cause: Ignition electrode or cable shorted.
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Dometic's checks, in order: Reset the error; contact a service agent if it returns.
Parts these checks can point to
Source: Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN), page 44. Open the PDF
Where this comes from
Dometic RUA5208X, RUA6408X, RUA8408X operating manual APAC (EN), published by Dometic. Open the PDF
We don't invent fault codes or part numbers. Each code above carries the page it came from.