Error 1GASControl senses a flame while the gas supply should be off.

Likely cause: Electronics glitch, gas valve not closing, or power board fault.

Gas fault: get a licensed gas fitter

Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.

Thetford's checks, in order: Reset fridge and 12 V supply; fit Thetford error-1 kit if needed; test gas valve; replace board/kit by serial date.

Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 4. Open the PDF

Error 2Burner control module is giving incorrect feedback.

Likely cause: Burner control (power board) failure.

Thetford's checks, in order: Replace LED/LCD kit (pre-June 2015) or power board assembly (later), based on serial number.

Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 5. Open the PDF

Error 3GASGas lockout: flame did not ignite within 30 seconds.

Likely cause: Empty bottle or closed valve, no spark, electrode gap or damage, dirty burner jet, wrong gas pressure.

Gas fault: get a licensed gas fitter

Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.

Thetford's checks, in order: Check gas, spark and 4 mm electrode gap, clean burner and jet, check pressure, then gas valve or board.

Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 6. Open the PDF

Error 412 V DC heater is off when it should be on.

Likely cause: Loose connection, blown 20 A fuse, or failed DC heater element.

Thetford's checks, in order: Check connections and 20 A fuse, measure heater current and resistance; replace DC heater or board.

Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 8. Open the PDF

Error 512 V DC heater is on when it should be off.

Likely cause: Power board fault.

Thetford's checks, in order: Reset the fridge; if it persists replace LED/LCD kit or power board by serial date.

Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 9. Open the PDF

Error 612 V supply voltage is out of range.

Likely cause: Vehicle supply problem, blown fuse, or solar regulator overcharging.

Thetford's checks, in order: Check supply voltage and fuse; disconnect solar to test; otherwise replace board.

Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 10. Open the PDF

Error 7No engine-running (D+) signal while set to manual 12 V.

Likely cause: Engine off, D+ wire faulty or reversed, or weak supply.

Thetford's checks, in order: Check D+ input voltage and polarity with engine running; otherwise replace board.

Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 11. Open the PDF

Error 8230 V heater current is far below normal.

Likely cause: Mains out of range, blown 2 A fuse, or failed AC heater element.

Thetford's checks, in order: Check mains and fuse, measure heater current and resistance; replace AC heater or board.

Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 12. Open the PDF

Error 9230 V heater is on when it should be off.

Likely cause: Power board fault.

Thetford's checks, in order: Reset the fridge; if it persists replace LED/LCD kit or power board by serial date.

Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 13. Open the PDF

Error 10230 V mains supply is out of range.

Likely cause: Mains voltage at the fridge too low or too high.

Thetford's checks, in order: Check site or inverter supply; if supply is fine replace board.

Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 14. Open the PDF

Error 11Auto mode found no energy source available.

Likely cause: No gas, mains or 12 V available, or a board fault.

Thetford's checks, in order: Make sure a source is available; test each source manually to see which error appears.

Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 15. Open the PDF

Error 12Display board and power board have lost communication.

Likely cause: Low 12 V supply, bent pins or damaged cable between boards.

Thetford's checks, in order: Check 12 V, inspect plugs and pins, check comms voltage; replace cable or board.

Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 16. Open the PDF

Error 13Thermistor failed; fridge runs in backup mode.

Likely cause: Thermistor missing, unplugged, damaged cable or loom pins.

Thetford's checks, in order: Check thermistor fitted and plugged in, check loom and cable; replace thermistor or board.

Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 18. Open the PDF