Thetford fridge
Thetford N3000 fridge error codes (N3080-N3175)
All 13 codes, what each one means and what to check, from Thetford Troubleshooting N3000 series absorption refrigerator (EN).
Error 1GASControl senses a flame while the gas supply should be off.
Likely cause: Electronics glitch, gas valve not closing, or power board fault.
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Thetford's checks, in order: Reset fridge and 12 V supply; fit Thetford error-1 kit if needed; test gas valve; replace board/kit by serial date.
Parts these checks can point to
Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 4. Open the PDF
Error 2Burner control module is giving incorrect feedback.
Likely cause: Burner control (power board) failure.
Thetford's checks, in order: Replace LED/LCD kit (pre-June 2015) or power board assembly (later), based on serial number.
Parts these checks can point to
Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 5. Open the PDF
Error 3GASGas lockout: flame did not ignite within 30 seconds.
Likely cause: Empty bottle or closed valve, no spark, electrode gap or damage, dirty burner jet, wrong gas pressure.
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Thetford's checks, in order: Check gas, spark and 4 mm electrode gap, clean burner and jet, check pressure, then gas valve or board.
Parts these checks can point to
Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 6. Open the PDF
Error 412 V DC heater is off when it should be on.
Likely cause: Loose connection, blown 20 A fuse, or failed DC heater element.
Thetford's checks, in order: Check connections and 20 A fuse, measure heater current and resistance; replace DC heater or board.
Parts these checks can point to
Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 8. Open the PDF
Error 512 V DC heater is on when it should be off.
Likely cause: Power board fault.
Thetford's checks, in order: Reset the fridge; if it persists replace LED/LCD kit or power board by serial date.
Parts these checks can point to
Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 9. Open the PDF
Error 612 V supply voltage is out of range.
Likely cause: Vehicle supply problem, blown fuse, or solar regulator overcharging.
Thetford's checks, in order: Check supply voltage and fuse; disconnect solar to test; otherwise replace board.
Parts these checks can point to
Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 10. Open the PDF
Error 7No engine-running (D+) signal while set to manual 12 V.
Likely cause: Engine off, D+ wire faulty or reversed, or weak supply.
Thetford's checks, in order: Check D+ input voltage and polarity with engine running; otherwise replace board.
Parts these checks can point to
Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 11. Open the PDF
Error 8230 V heater current is far below normal.
Likely cause: Mains out of range, blown 2 A fuse, or failed AC heater element.
Thetford's checks, in order: Check mains and fuse, measure heater current and resistance; replace AC heater or board.
Parts these checks can point to
Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 12. Open the PDF
Error 9230 V heater is on when it should be off.
Likely cause: Power board fault.
Thetford's checks, in order: Reset the fridge; if it persists replace LED/LCD kit or power board by serial date.
Parts these checks can point to
Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 13. Open the PDF
Error 10230 V mains supply is out of range.
Likely cause: Mains voltage at the fridge too low or too high.
Thetford's checks, in order: Check site or inverter supply; if supply is fine replace board.
Parts these checks can point to
Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 14. Open the PDF
Error 11Auto mode found no energy source available.
Likely cause: No gas, mains or 12 V available, or a board fault.
Thetford's checks, in order: Make sure a source is available; test each source manually to see which error appears.
Parts these checks can point to
Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 15. Open the PDF
Error 12Display board and power board have lost communication.
Likely cause: Low 12 V supply, bent pins or damaged cable between boards.
Thetford's checks, in order: Check 12 V, inspect plugs and pins, check comms voltage; replace cable or board.
Parts these checks can point to
Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 16. Open the PDF
Error 13Thermistor failed; fridge runs in backup mode.
Likely cause: Thermistor missing, unplugged, damaged cable or loom pins.
Thetford's checks, in order: Check thermistor fitted and plugged in, check loom and cable; replace thermistor or board.
Parts these checks can point to
Source: Thetford Troubleshooting N3000 series absorption refrigerator (EN), page 18. Open the PDF
Where this comes from
Thetford Troubleshooting N3000 series absorption refrigerator (EN), published by Thetford. Open the PDF
We don't invent fault codes or part numbers. Each code above carries the page it came from.