Thetford fridge
Thetford N3141 / N3142 slimline fridge error codes
All 13 codes, what each one means and what to check, from Thetford Troubleshooting N3141 & N3142 absorption refrigerator (EN).
Error 1GASControl senses a flame while the gas supply should be off.
Likely cause: Gas valve not closing, or power board fault.
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Thetford's checks, in order: Switch off and on; test the gas valve; replace power board assembly.
Parts these checks can point to
Source: Thetford Troubleshooting N3141 & N3142 absorption refrigerator (EN), page 4. Open the PDF
Error 2Burner control module is giving incorrect feedback.
Likely cause: Burner control (power board) failure.
Thetford's checks, in order: Replace the power board assembly.
Parts these checks can point to
Source: Thetford Troubleshooting N3141 & N3142 absorption refrigerator (EN), page 5. Open the PDF
Error 3GASGas lockout: flame did not ignite within 30 seconds (retries 3 times if flame lost).
Likely cause: Empty bottle or closed valve, no spark, electrode gap, dirty burner, gas pressure out of 30-35 mbar.
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Thetford's checks, in order: Check gas, spark and 4 mm electrode gap, clean burner, check pressure, then gas valve or board.
Parts these checks can point to
Source: Thetford Troubleshooting N3141 & N3142 absorption refrigerator (EN), page 6. Open the PDF
Error 412 V DC heater is off when it should be on.
Likely cause: Loose connection, blown 20 A fuse, or failed DC heater.
Thetford's checks, in order: Check connections and fuse, measure heater current (about 15 A) and resistance; replace heater or board.
Parts these checks can point to
Source: Thetford Troubleshooting N3141 & N3142 absorption refrigerator (EN), page 8. Open the PDF
Error 512 V DC heater is on when it should be off.
Likely cause: Power board fault.
Thetford's checks, in order: Reset; if it persists replace the power board assembly.
Parts these checks can point to
Source: Thetford Troubleshooting N3141 & N3142 absorption refrigerator (EN), page 9. Open the PDF
Error 612 V supply voltage is out of range.
Likely cause: Vehicle supply problem, blown fuse, or solar regulator overcharging.
Thetford's checks, in order: Check supply voltage and fuse; disconnect solar to test; otherwise replace board.
Parts these checks can point to
Source: Thetford Troubleshooting N3141 & N3142 absorption refrigerator (EN), page 10. Open the PDF
Error 7No engine-running (D+) signal while set to manual 12 V.
Likely cause: Engine off, D+ wire faulty or reversed.
Thetford's checks, in order: Check D+ input voltage and polarity with engine running; otherwise replace board.
Parts these checks can point to
Source: Thetford Troubleshooting N3141 & N3142 absorption refrigerator (EN), page 11. Open the PDF
Error 8230 V heater current is far below normal.
Likely cause: Mains out of range, blown fuse, or failed AC heater.
Thetford's checks, in order: Check mains and fuse, measure heater current and resistance; replace AC heater or board.
Parts these checks can point to
Source: Thetford Troubleshooting N3141 & N3142 absorption refrigerator (EN), page 12. Open the PDF
Error 9230 V heater is on when it should be off.
Likely cause: Power board fault.
Thetford's checks, in order: Reset; if it persists replace the power board assembly.
Parts these checks can point to
Source: Thetford Troubleshooting N3141 & N3142 absorption refrigerator (EN), page 13. Open the PDF
Error 10230 V mains supply is out of range.
Likely cause: Mains voltage at the fridge too low or too high.
Thetford's checks, in order: Check supply; if fine replace the power board assembly.
Parts these checks can point to
Source: Thetford Troubleshooting N3141 & N3142 absorption refrigerator (EN), page 14. Open the PDF
Error 11Auto mode found no energy source available.
Likely cause: No source available, or a board fault.
Thetford's checks, in order: Make sure a source is available; test each source manually.
Parts these checks can point to
Source: Thetford Troubleshooting N3141 & N3142 absorption refrigerator (EN), page 15. Open the PDF
Error 12Display board and power board have lost communication.
Likely cause: Low 12 V, bent pins or damaged cable between boards.
Thetford's checks, in order: Check 12 V and plugs, check comms voltage; replace cable or board.
Parts these checks can point to
Source: Thetford Troubleshooting N3141 & N3142 absorption refrigerator (EN), page 16. Open the PDF
Error 13Thermistor failed; fridge runs in backup mode.
Likely cause: Thermistor missing, unplugged, damaged cable or loom pins.
Thetford's checks, in order: Check thermistor fitting, plug and cable; replace thermistor or board.
Parts these checks can point to
Source: Thetford Troubleshooting N3141 & N3142 absorption refrigerator (EN), page 18. Open the PDF
Where this comes from
Thetford Troubleshooting N3141 & N3142 absorption refrigerator (EN), published by Thetford. Open the PDF
We don't invent fault codes or part numbers. Each code above carries the page it came from.