Thetford fridge
Thetford N4000 fridge error codes (N4080-N4175)
All 14 codes, what each one means and what to check, from Thetford Troubleshooting N4000 absorption refrigerator (EN, version 05-2019).
Error 1GASControl senses a flame while the gas supply should be off.
Likely cause: Gas valve not closing fully, or a power board fault.
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Thetford's checks, in order: Switch fridge off and on; if it returns, test the gas valve, then replace the power board.
Source: Thetford Troubleshooting N4000 absorption refrigerator (EN, version 05-2019), page 4. Open the PDF
Error 2Burner control module is giving incorrect feedback to the control.
Likely cause: Burner control (power board) failure.
Thetford's checks, in order: Replace the power board.
Source: Thetford Troubleshooting N4000 absorption refrigerator (EN, version 05-2019), page 5. Open the PDF
Error 3GASGas lockout: flame did not ignite within 30 seconds.
Likely cause: Empty bottle or closed valve, no spark, electrode gap or damage, dirty burner jet, gas pressure out of 30-35 mbar range.
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Thetford's checks, in order: Check gas supply, spark and 4 mm electrode gap, clean burner and jet, check gas pressure, then gas valve or power board.
Source: Thetford Troubleshooting N4000 absorption refrigerator (EN, version 05-2019), page 6. Open the PDF
Error 412 V DC heater is off when it should be on.
Likely cause: Loose connection, blown 25 A fuse, or a failed DC heater element.
Thetford's checks, in order: Check connections and 25 A fuse, measure heater current and resistance; replace the DC heater or power board.
Source: Thetford Troubleshooting N4000 absorption refrigerator (EN, version 05-2019), page 8. Open the PDF
Error 512 V DC heater is on when it should be off.
Likely cause: Power board fault.
Thetford's checks, in order: Switch off and on to reset; if it persists replace the power board.
Source: Thetford Troubleshooting N4000 absorption refrigerator (EN, version 05-2019), page 9. Open the PDF
Error 612 V supply voltage is outside 10-15 V.
Likely cause: Vehicle supply problem, blown 25 A fuse, or a solar regulator feeding excess voltage.
Thetford's checks, in order: Check supply voltage and 25 A fuse; disconnect solar to test; otherwise replace the power board.
Source: Thetford Troubleshooting N4000 absorption refrigerator (EN, version 05-2019), page 10. Open the PDF
Error 7No engine-running (D+) signal while the fridge is set to manual 12 V.
Likely cause: Engine off, D+ wire faulty or reversed, or supply cannot deliver enough current.
Thetford's checks, in order: Check the D+ input is 10-15 V with engine running and polarity is correct; else replace power board.
Source: Thetford Troubleshooting N4000 absorption refrigerator (EN, version 05-2019), page 11. Open the PDF
Error 8230 V heater current is far below normal (over 75% low).
Likely cause: Mains outside 190-260 V, blown 2 A fuse, or failed AC heater element.
Thetford's checks, in order: Check mains voltage and 2 A fuse, measure heater current and resistance; replace AC heater or power board.
Source: Thetford Troubleshooting N4000 absorption refrigerator (EN, version 05-2019), page 12. Open the PDF
Error 9230 V heater is on when it should be off.
Likely cause: Power board fault.
Thetford's checks, in order: Switch off and on to reset; if it persists replace the power board.
Source: Thetford Troubleshooting N4000 absorption refrigerator (EN, version 05-2019), page 13. Open the PDF
Error 10230 V mains supply is out of range.
Likely cause: Mains below 190 V or above 260 V at the fridge.
Thetford's checks, in order: Check site or inverter supply voltage; if supply is fine, replace the power board.
Source: Thetford Troubleshooting N4000 absorption refrigerator (EN, version 05-2019), page 14. Open the PDF
Error 11Auto mode found no energy source available.
Likely cause: No gas, mains or 12 V available, or a power board fault.
Thetford's checks, in order: Make sure a source is available; select each source manually to see which error appears.
Source: Thetford Troubleshooting N4000 absorption refrigerator (EN, version 05-2019), page 15. Open the PDF
Error 12Display board and power board have lost communication.
Likely cause: Low 12 V supply, tripped resettable fuse, bent pins or damaged cable between boards.
Thetford's checks, in order: Check 12 V, disconnect 5 minutes, inspect plugs; check 5 V on comms lines; replace cable or power board.
Source: Thetford Troubleshooting N4000 absorption refrigerator (EN, version 05-2019), page 16. Open the PDF
Error 13Thermistor (temperature sensor) failed; fridge runs in backup mode.
Likely cause: Thermistor missing, unplugged, damaged cable or loom pins.
Thetford's checks, in order: Check thermistor fitted and plugged in, check loom and cable continuity; replace thermistor or power board.
Source: Thetford Troubleshooting N4000 absorption refrigerator (EN, version 05-2019), page 18. Open the PDF
Error 18All symbols light up briefly at start-up.
Likely cause: Normal start-up routine; if lights keep blinking, an electronics fault.
Thetford's checks, in order: Wait a few seconds; if it continues switch off and on, then contact a service centre.
Source: Thetford N4000 user manual (EN, 691829 0424 V07), page 21. Open the PDF
Where this comes from
Thetford Troubleshooting N4000 absorption refrigerator (EN, version 05-2019), published by Thetford. Open the PDF
We don't invent fault codes or part numbers. Each code above carries the page it came from.