SparePartsMatcher

Thetford fridge

Thetford Premium LCD line fridge error codes (N90-N180)

All 14 codes, what each one means and what to check, from Thetford Troubleshooting absorption refrigerators Premium LCD line (EN).

Error 1230 V heater current is far below normal.

Likely cause: Mains outside 210-240 V, blown 5 A fuse, or failed AC heater.

Thetford's checks, in order: Check mains and 5 A fuse, check heater resistance and replace AC heater. Thetford states no replacement power board is available.

Source: Thetford Troubleshooting absorption refrigerators Premium LCD line (EN), page 2. Open the PDF

Error 212 V DC heater current is far below normal.

Likely cause: Supply or D+ outside 10.5-15.4 V, loose wiring, blown 20 A fuse, or failed DC heater.

Thetford's checks, in order: Check supply, D+, connections and 20 A fuse; check heater resistance and replace DC heater.

Source: Thetford Troubleshooting absorption refrigerators Premium LCD line (EN), page 3. Open the PDF

Error 3230 V heater is on when it should be off.

Likely cause: Power board fault (mains supply checked first).

Thetford's checks, in order: Confirm mains 210-240 V; otherwise the power board has failed. Thetford states no replacement power board is available.

Source: Thetford Troubleshooting absorption refrigerators Premium LCD line (EN), page 4. Open the PDF

Error 412 V DC heater is on when it should be off.

Likely cause: Power board fault, or D+ wiring polarity wrong.

Thetford's checks, in order: Check 12 V and D+ voltage and polarity; otherwise power board has failed. Thetford states no replacement power board is available.

Source: Thetford Troubleshooting absorption refrigerators Premium LCD line (EN), page 4. Open the PDF

Error 5GASControl senses a flame while gas should be off.

Likely cause: Gas valve not closing, or power board fault.

Gas fault: get a licensed gas fitter

Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.

Thetford's checks, in order: Test the gas valve and replace if faulty; otherwise power board has failed.

Source: Thetford Troubleshooting absorption refrigerators Premium LCD line (EN), page 5. Open the PDF

Error 6GASGas output terminal reads on when it should be off.

Likely cause: Power board fault.

Gas fault: get a licensed gas fitter

Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.

Thetford's checks, in order: Power board has failed. Thetford states no replacement power board is available.

Source: Thetford Troubleshooting absorption refrigerators Premium LCD line (EN), page 5. Open the PDF

Error 7GASGas output terminal reads off when it should be on.

Likely cause: Power board fault.

Gas fault: get a licensed gas fitter

Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.

Thetford's checks, in order: Power board has failed. Thetford states no replacement power board is available.

Source: Thetford Troubleshooting absorption refrigerators Premium LCD line (EN), page 5. Open the PDF

Error 8230 V mains supply is below 20% of nominal.

Likely cause: Mains supply missing or low, or blown 4 A glass fuse.

Thetford's checks, in order: Check mains 210-240 V and the 4 A glass fuse; otherwise power board has failed.

Source: Thetford Troubleshooting absorption refrigerators Premium LCD line (EN), page 6. Open the PDF

Error 9GASGas lockout: flame did not ignite within 30 seconds.

Likely cause: No gas, no spark, electrode gap or damage, dirty burner jet, gas pressure out of 28-30 mbar.

Gas fault: get a licensed gas fitter

Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.

Thetford's checks, in order: Check gas, spark and 4 mm electrode gap, clean burner and jet, check pressure and gas valve.

Source: Thetford Troubleshooting absorption refrigerators Premium LCD line (EN), page 7. Open the PDF

Error 10No engine-running (D+) signal while set to manual 12 V.

Likely cause: Engine off, D+ wire faulty or reversed, blown 20 A fuse.

Thetford's checks, in order: Check supply and D+ 9.5-15.5 V and polarity, check 20 A fuse.

Source: Thetford Troubleshooting absorption refrigerators Premium LCD line (EN), page 8. Open the PDF

Error 11Auto mode found no energy source available.

Likely cause: No source available, or a power board fault.

Thetford's checks, in order: Make sure all sources are available; select each manually to see which error appears.

Source: Thetford Troubleshooting absorption refrigerators Premium LCD line (EN), page 9. Open the PDF

Error 1212 V supply is outside 9.5-15.5 V.

Likely cause: Vehicle supply problem, solar regulator overcharging, or blown 2 A fuse.

Thetford's checks, in order: Check supply voltage, disconnect solar to test, check 2 A fuse.

Source: Thetford Troubleshooting absorption refrigerators Premium LCD line (EN), page 10. Open the PDF

Error 13Thermistor failed; fridge switches to backup mode (BOS).

Likely cause: Thermistor missing, unplugged, loom not connected or bent pins.

Thetford's checks, in order: Fit thermistor 623077 on the 5th fin from the right, check loom and pins.

Source: Thetford Troubleshooting absorption refrigerators Premium LCD line (EN), page 11. Open the PDF

Error 14Display board and power board have lost communication.

Likely cause: Low 12 V supply, blown 2 A glass fuse, or bad connection between boards.

Thetford's checks, in order: Check 12 V and 2 A fuse, restore connections or replace the display board.

Source: Thetford Troubleshooting absorption refrigerators Premium LCD line (EN), page 12. Open the PDF

Where this comes from

Thetford Troubleshooting absorption refrigerators Premium LCD line (EN), published by Thetford. Open the PDF

We don't invent fault codes or part numbers. Each code above carries the page it came from.