Truma hot water system
Truma Combi D (diesel) heater - CP classic analogue panel flash codes
All 11 codes, what each one means and what to check, from Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides.
Red LED x6Out of diesel: fuel not reaching the heater.
Likely cause: Low or empty fuel tank, or vehicle parked on a slope.
Truma's checks, in order: Refill the tank, then prime the fuel line as in the initial start-up instructions.
Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 9. Open the document
Red LED (not x6) / steadyHeater malfunction.
Likely cause: Internal heater fault.
Truma's checks, in order: Contact Truma service.
Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 9. Open the document
Yellow LED x1Battery voltage getting low (below 11.5 V).
Likely cause: Leisure battery discharged or ageing.
Truma's checks, in order: Charge the battery.
Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 7. Open the document
Yellow LED x2Voltage too low (below 10.2 V) or too high (above 16.4 V); Combi D E also no 230 V.
Likely cause: Flat/old battery, faulty charger, or on Combi E: no mains, blown 230 V fuse, overheat cut-out tripped.
Truma's checks, in order: Charge or replace battery, check charger; Combi E: restore 230 V, replace 230 V fuse or reset overheat button.
Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 7. Open the document
Yellow LED x3Window above the flue cowl is open (window switch).
Likely cause: Window over the cowl open, or window switch/cable faulty.
Truma's checks, in order: Close the window; if it is closed, check the window switch.
Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 7. Open the document
Yellow LED x4Warm-air or water temperature too high.
Likely cause: Summer mode with empty water tank, blocked warm-air outlets or blocked return-air intake.
Truma's checks, in order: Switch off and let cool; fill boiler with water; clear outlets and intake.
Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 8. Open the document
Yellow LED x5Room temperature sensor or its cable faulty.
Likely cause: Damaged sensor, broken or unplugged sensor cable.
Truma's checks, in order: Contact a Truma service agent to test sensor and cable.
Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 8. Open the document
Yellow LED x6Water temperature too high in summer (hot water only) mode.
Likely cause: Boiler empty or low.
Truma's checks, in order: Fill the boiler with water.
Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 10. Open the document
Yellow LED x7Control panel or control panel cable faulty.
Likely cause: Damaged panel, loose or broken panel cable.
Truma's checks, in order: Contact a Truma service agent; check panel cable plugs.
Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 8. Open the document
Yellow LED x8FrostControl heating element has short-circuited.
Likely cause: Faulty FrostControl heating element.
Truma's checks, in order: Unplug the heating element from the electronics and replace the element.
Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 8. Open the document
Green LED flashing fastNot a fault: after-run fan cooling the heater.
Likely cause: Normal after-run (up to 5 minutes).
Truma's checks, in order: No action needed; it stops by itself.
Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 8. Open the document
Where this comes from
Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, published by Truma. Open the document
We don't invent fault codes or part numbers. Each code above carries the page it came from.