Truma VarioHeat - CP classic VarioHeat analogue panel flash codes
All 6 codes, what each one means and what to check, from Truma VarioHeat (eco / comfort) - operating instructions with CP plus VarioHeat and CP classic VarioHeat (39050-00070, rev 00, 07/2016).
Red LED x1GASNo flame: gas supply problem.
Likely cause: Valve closed, cylinder empty, regulator iced, too much butane, or blocked air intake/exhaust.
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Truma's checks, in order: Open valves, change cylinder, use EisEx and propane, clear the cowl.
Source: Truma VarioHeat (eco / comfort) - operating instructions with CP plus VarioHeat and CP classic VarioHeat (39050-00070, rev 00, 07/2016), page 29. Open the PDF
Red LED x2Heater fault.
Likely cause: Internal heater fault.
Truma's checks, in order: Contact Truma service.
Source: Truma VarioHeat (eco / comfort) - operating instructions with CP plus VarioHeat and CP classic VarioHeat (39050-00070, rev 00, 07/2016), page 29. Open the PDF
Red LED x3Battery voltage too low (below 10.4 V / 10 V) or too high (above 16.4 V).
Likely cause: Flat or old battery, or faulty charger.
Truma's checks, in order: Charge or replace the battery; check charger.
Source: Truma VarioHeat (eco / comfort) - operating instructions with CP plus VarioHeat and CP classic VarioHeat (39050-00070, rev 00, 07/2016), page 29. Open the PDF
Red LED x4Window above the cowl open (window switch).
Likely cause: Window open or switch faulty.
Truma's checks, in order: Close the window.
Source: Truma VarioHeat (eco / comfort) - operating instructions with CP plus VarioHeat and CP classic VarioHeat (39050-00070, rev 00, 07/2016), page 29. Open the PDF
Red LED x5Warm-air flow blocked.
Likely cause: Warm-air outlets or return-air intake blocked.
Truma's checks, in order: Remove the blockage.
Source: Truma VarioHeat (eco / comfort) - operating instructions with CP plus VarioHeat and CP classic VarioHeat (39050-00070, rev 00, 07/2016), page 29. Open the PDF
Red LED x6Fan motor nearing its wear limit.
Likely cause: Worn heater fan motor.
Truma's checks, in order: Contact Truma service.
Source: Truma VarioHeat (eco / comfort) - operating instructions with CP plus VarioHeat and CP classic VarioHeat (39050-00070, rev 00, 07/2016), page 29. Open the PDF