Truma heater
Truma VarioHeat - CP plus VarioHeat panel fault codes (EU edition)
All 10 codes, what each one means and what to check, from Truma VarioHeat (eco / comfort) - operating instructions with CP plus VarioHeat and CP classic VarioHeat (39050-00070, rev 00, 07/2016).
#2GASNo flame detected at the burner.
Likely cause: Gas closed or empty, iced regulator, too much butane, or blocked air intake/exhaust.
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Truma's checks, in order: Open valves, change cylinder, use EisEx and propane, clear the cowl of ice or debris.
Source: Truma VarioHeat (eco / comfort) - operating instructions with CP plus VarioHeat and CP classic VarioHeat (39050-00070, rev 00, 07/2016), page 28. Open the PDF
#7Room temperature sensor disconnected or cable faulty.
Likely cause: Sensor unplugged or cable damaged.
Truma's checks, in order: Contact Truma service.
Source: Truma VarioHeat (eco / comfort) - operating instructions with CP plus VarioHeat and CP classic VarioHeat (39050-00070, rev 00, 07/2016), page 28. Open the PDF
#11Temperature cut-out has tripped.
Likely cause: Heater overheated.
Truma's checks, in order: Contact Truma service.
Source: Truma VarioHeat (eco / comfort) - operating instructions with CP plus VarioHeat and CP classic VarioHeat (39050-00070, rev 00, 07/2016), page 28. Open the PDF
#25Voltage too high (above 16.4 V).
Likely cause: Faulty charger or other voltage source.
Truma's checks, in order: Check battery voltage and charger.
Source: Truma VarioHeat (eco / comfort) - operating instructions with CP plus VarioHeat and CP classic VarioHeat (39050-00070, rev 00, 07/2016), page 28. Open the PDF
#26Voltage too low (below 10 V).
Likely cause: Flat or worn battery.
Truma's checks, in order: Charge the battery; replace if old.
Source: Truma VarioHeat (eco / comfort) - operating instructions with CP plus VarioHeat and CP classic VarioHeat (39050-00070, rev 00, 07/2016), page 28. Open the PDF
#27Warm-air flow blocked.
Likely cause: Warm-air outlets, return-air intake or duct end outlets closed or blocked.
Truma's checks, in order: Clear blockages and open the end outlets.
Source: Truma VarioHeat (eco / comfort) - operating instructions with CP plus VarioHeat and CP classic VarioHeat (39050-00070, rev 00, 07/2016), page 28. Open the PDF
#28Window above the cowl open (window switch).
Likely cause: Window open or window switch faulty.
Truma's checks, in order: Close the window.
Source: Truma VarioHeat (eco / comfort) - operating instructions with CP plus VarioHeat and CP classic VarioHeat (39050-00070, rev 00, 07/2016), page 28. Open the PDF
#29Battery voltage getting low (below 10.4 V).
Likely cause: Battery discharging.
Truma's checks, in order: Charge the battery.
Source: Truma VarioHeat (eco / comfort) - operating instructions with CP plus VarioHeat and CP classic VarioHeat (39050-00070, rev 00, 07/2016), page 28. Open the PDF
#32Fan motor nearing its wear limit.
Likely cause: Worn heater fan motor.
Truma's checks, in order: Contact Truma service before it fails.
Source: Truma VarioHeat (eco / comfort) - operating instructions with CP plus VarioHeat and CP classic VarioHeat (39050-00070, rev 00, 07/2016), page 28. Open the PDF
#255Heater not talking to the control panel.
Likely cause: Panel cable or main fuse faulty, or cable disconnected.
Truma's checks, in order: Contact Truma service; check panel cable and fuse.
Source: Truma VarioHeat (eco / comfort) - operating instructions with CP plus VarioHeat and CP classic VarioHeat (39050-00070, rev 00, 07/2016), page 28. Open the PDF