Aircommand air conditioner
Aircommand SANDPIPER air conditioner parts
Every part for your air conditioner, checked against Aircommand's own parts lists.
Parts for your SANDPIPER.
Tap a part to see its price and where to buy it.
- Electronc kit #4 aircommPart no. 5601069
- Remote control gp05-01 aircommPart no. 5601071
- Filter sandpiperPart no. 7001002
- Fan inside sandpiperPart no. 7001003
- Thermostat switch sandpiperPart no. 7001004
- Fan outside sandpiperPart no. 7001005
- Vent grill sandpiper/jabiruPart no. 6102092
- Shroud top foam sandpiperPart no. 7001006
Showing 8 of 10 parts
See all 10 partsA code on the display?
8 fault codes for the SANDPIPER, from Aircommand's own documents. Tap one to see what to check.
E1Return-air (room) temperature sensor fault.
Likely cause: Sensor unplugged, damaged lead or failed sensor.
Aircommand's checks, in order: Contact Aircommand Australia or an authorised service agent.
Source: Aircommand Sandpiper owners manual / installation guide (Rev 7, 28 May 2013), page 20. Open the PDF
E2Inside coil temperature sensor fault.
Likely cause: Sensor unplugged, damaged lead or failed sensor.
Aircommand's checks, in order: Contact Aircommand Australia or an authorised service agent.
Source: Aircommand Sandpiper owners manual / installation guide (Rev 7, 28 May 2013), page 20. Open the PDF
E3Outside coil temperature sensor fault.
Likely cause: Sensor unplugged, damaged lead or failed sensor.
Aircommand's checks, in order: Contact Aircommand Australia or an authorised service agent.
Source: Aircommand Sandpiper owners manual / installation guide (Rev 7, 28 May 2013), page 20. Open the PDF
E4Inside coil is not cooling.
Likely cause: Compressor not running or low refrigerant.
Aircommand's checks, in order: Contact Aircommand Australia or an authorised service agent.
Source: Aircommand Sandpiper owners manual / installation guide (Rev 7, 28 May 2013), page 20. Open the PDF
E5Outside coil over temperature.
Likely cause: Condenser airflow blocked or condenser fan not running.
Aircommand's checks, in order: Contact Aircommand Australia or an authorised service agent.
Source: Aircommand Sandpiper owners manual / installation guide (Rev 7, 28 May 2013), page 20. Open the PDF
E15Communication error between control pad and main board.
Likely cause: Loose connection or failed control pad.
Aircommand's checks, in order: Check connections or replace the control pad; contact Aircommand Australia.
Source: Aircommand Sandpiper owners manual / installation guide (Rev 7, 28 May 2013), page 20. Open the PDF
Show all 8 codes
E18Ambient temperature sensor error.
Likely cause: Sensor or wiring fault.
Aircommand's checks, in order: Contact Aircommand Australia or an authorised service agent.
Source: Aircommand Sandpiper owners manual / installation guide (Rev 7, 28 May 2013), page 20. Open the PDF
E21Outdoor air temperature sensor error.
Likely cause: Sensor or wiring fault.
Aircommand's checks, in order: Contact Aircommand Australia or an authorised service agent.
Source: Aircommand Sandpiper owners manual / installation guide (Rev 7, 28 May 2013), page 20. Open the PDF
Documents for the SANDPIPER2 documents from Aircommand
- SANDPIPER spare parts listParts list · released 22 Nov 2016
- Aircommand Sandpiper owners manual / installation guide (Rev 7, 28 May 2013)Manual · released 28 May 2013 · Open the PDF
Where these numbers come from
We don't invent part numbers. Every number on this page is copied from Aircommand's documents listed above, with the page. If a document is in doubt we hold the part back and say so.
Not sure it's an SANDPIPER?
On a roof-top air conditioner it's on the ceiling unit inside: take off the return-air grille or lift out the filter and look up. Otherwise it's on the roof unit under the shroud.
How to read the plate All Aircommand modelsAll 10 parts for the SANDPIPER
Every part Aircommand's documents list for the SANDPIPER, grouped by area. Tap a part for its price, where to buy it and the page it came from.
Prices last seen between 27 Oct 2026 and 1 Nov 2026. Each price shows its own date. The shop's own page is final.
Electrical6 parts
-
Callout 1 · SANDPIPER spare parts list
None in stock 4 shops list it · last seen 1 Nov
Compare 4 shops -
Callout 3 · SANDPIPER spare parts list
None in stock 2 shops list it · last seen 27 Oct
Compare 2 shops -
Callout 4 · SANDPIPER spare parts list
None in stock 2 shops list it · last seen 27 Oct
Compare 2 shops -
Callout 5 · SANDPIPER spare parts list
None in stock 2 shops list it · last seen 27 Oct
Compare 2 shops -
Remote control gp05-01 aircomm
Callout 8 · SANDPIPER spare parts list
None in stock 1 shop lists it · last seen 27 Oct
Where to buy -
Callout 10 · SANDPIPER spare parts list
No Australian stockist yet
Covers & fittings4 parts
-
Callout 2 · SANDPIPER spare parts list
None in stock 2 shops list it · last seen 27 Oct
Compare 2 shops -
Callout 6 · SANDPIPER spare parts list
No Australian stockist yet
-
Callout 7 · SANDPIPER spare parts list
No Australian stockist yet
-
Callout 9 · SANDPIPER spare parts list
No Australian stockist yet
What the fit words mean
- Very likely fits 10 parts. From the maker's documents for this model, with a condition or a caveat we explain on the part.
Why 10 parts here aren't marked "Fits": Listed against this model in the Airconditioner sandpiper parts list.
Parts shared across a range are often named after the first model they were made for, so a name may mention a different model. That doesn't mean it won't fit yours.
Is this my air conditioner?
Check the plate on your air conditioner says SANDPIPER.
- MOD. NO.
- SANDPIPER
- Item or product code
- 7000001
- SKU
- 9108400699
On a roof-top air conditioner it's on the ceiling unit inside: take off the return-air grille or lift out the filter and look up. Otherwise it's on the roof unit under the shroud.
Where's the plate on a Aircommand air conditioner?
Not your model? See all Aircommand models or ask us to find it.