Truma Combi gas heater - CP classic analogue panel flash codes

All 10 codes, what each one means and what to check, from Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides.

Yellow LED x1Battery voltage getting low (below 10.4 V); heater keeps running.

Likely cause: Leisure battery discharged or ageing.

Truma's checks, in order: Charge the battery.

Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 7. Open the document

Yellow LED x2Heater stopped: voltage too low (below 10.0 V) or too high (above 16.4 V); Combi E also no 230 V.

Likely cause: Flat/old battery, faulty charger, or on Combi E: no mains, blown 230 V fuse, overheat cut-out tripped.

Truma's checks, in order: Charge or replace battery, check charger; Combi E: restore 230 V, replace 230 V fuse or reset overheat button.

Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 7. Open the document

Yellow LED x3Window above the flue cowl is open (window switch).

Likely cause: Window over the cowl open, or window switch/cable faulty.

Truma's checks, in order: Close the window; if it is closed, check the window switch.

Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 7. Open the document

Yellow LED x4Overheating shutdown after running a while.

Likely cause: Summer mode with empty water tank, blocked warm-air outlets or blocked return-air intake.

Truma's checks, in order: Switch off and let cool; fill boiler with water; clear outlets and intake.

Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 8. Open the document

Yellow LED x5Room temperature sensor or its cable faulty.

Likely cause: Damaged sensor, broken or unplugged sensor cable.

Truma's checks, in order: Contact a Truma service agent to test sensor and cable.

Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 8. Open the document

Yellow LED x7Control panel or control panel cable faulty.

Likely cause: Damaged panel, loose or broken panel cable.

Truma's checks, in order: Contact a Truma service agent; check panel cable plugs.

Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 8. Open the document

Yellow LED x8FrostControl drain-valve heating element has short-circuited.

Likely cause: Faulty FrostControl heating element.

Truma's checks, in order: Unplug the heating element from the electronics and replace the element.

Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 8. Open the document

Yellow LED x9GASNo gas flame: gas supply problem.

Likely cause: Cylinder empty or valve closed, regulator iced up, or too much butane in cold weather.

Gas fault: get a licensed gas fitter

Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.

Truma's checks, in order: Open/replace the cylinder, fit a regulator heater (EisEx), use propane.

Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 8. Open the document

Red LED x1-8Internal heater fault.

Likely cause: Fault inside the heater electronics or burner system.

Truma's checks, in order: Contact Truma service; the red LED on the heater electronics gives the detailed short/long flash code.

Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 8. Open the document

Green LED flashing fastNot a fault: after-run fan cooling the heater after switch-off.

Likely cause: Normal after-run (up to 5 minutes).

Truma's checks, in order: No action needed; it stops by itself.

Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 8. Open the document

Where this comes from

Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, published by Truma. Open the document

We don't invent fault codes or part numbers. Each code above carries the page it came from.