Truma hot water system
Truma Combi 4 E hot water system parts
Every part for your hot water system, checked against Truma's own parts lists.

Parts for your Combi 4 E.
Tap a part to see its price and where to buy it.
- Window switchPart no. 34030-34700
- Elbow bgc, blackPart no. 34092-01
- Cowl outer part zr 80, creamPart no. 36151-01
- Duct vr 80, ø 80 mmPart no. 39450-00
- Clamp zrs, ø 80 mmPart no. 39590-00
- Swivel air outlet scw 2, blackPart no. 39971-01
- End outlet en, blackPart no. 40171-05
- End outlet en-o, agate greyPart no. 40171-07
- Clamp zrs, ø 80 mmPart no. 39590-00
- Clamp üs, grey, ø 65 mmPart no. 40241-01
- Clamp üs 5, grey, ø 72 – 75 mmPart no. 40261-01
- New window switch, narrow, cpl.Part no. 34020-01581
- New wall cowl conversion kit combi d (e)Part no. 34020-01669
- Roof cowl kit cdPart no. 34122-01
- Zr 80 cowl inner partPart no. 36140-01
- Cowl outer part zr 80, light greyPart no. 36151-08
- End outlet nut em, agate greyPart no. 40181-01
- Blank cover cb, blackPart no. 34310-01
- Straight coupling kit + grille insertPart no. 34020-01438
- Clips 4 pcs.Part no. 34020-24000
- Cover bl 22, agate greyPart no. 40101-01
- Branch t at, agate greyPart no. 40131-01
- T-pipe lt, agate greyPart no. 40152-02
- Blank cover vd, agate greyPart no. 40353-01
- Elbow bgc, blackPart no. 34092-01
- Cowl outer part zr 80, creamPart no. 36151-01
- Duct vr 80, ø 80 mmPart no. 39450-00
- Swivel air outlet scw 2, blackPart no. 39971-01
- End outlet en, blackPart no. 40171-05
- End outlet en-o, agate greyPart no. 40171-07
- Lamellar insert la, blackPart no. 40721-05
- Elbow bg, blackPart no. 40740-01
Showing 8 of 78 parts
See all 78 partsA code on the display?
44 fault codes for the Combi 4 E, from Truma's own documents. Tap one to see what to check.
E 112 HGASGas cylinder empty
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Truma's checks, in order: Replace the gas cylinder
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
E 121 HGASGas cylinder or quick-acting valve in the gas supply line
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Truma's checks, in order: Check gas supply and open valves
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
E 122 HGASGas pressure regulation system iced up
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Truma's checks, in order: Use regulator heater (EisEx)
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
E 202 HGASButane content in the gas cylinder too high
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Truma's checks, in order: Use propane. Butane is unsuitable for heating, particularly at temperatures below 10 °C
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
E 211 HCombustion air infeed or exhaust outlet is sealed
Truma's checks, in order: Inspect openings for obstructions (slush, ice, leaves, etc.) and remove any obstructions
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
E 212 HGASGas pressure regulation system faulty
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Truma's checks, in order: Inspect / replace gas pressure regulation system
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
Show all 44 codes
E 507 HGASGas cylinder empty
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Truma's checks, in order: Replace the gas cylinder
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
E 516 HGASGas cylinder or quick-acting valve in the gas supply line closed
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Truma's checks, in order: Check gas supply and open valves
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
E 517 HGASGas pressure regulation system iced up; butane content in the gas cylinder too high; combustion air infeed or exhaust outlet is sealed; gas pressure regulation system faulty
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Truma's checks, in order: Use regulator heater (EisEx). Use propane — butane is unsuitable for heating, particularly at temperatures below 10 °C. Inspect openings for obstructions (slush, ice, leaves, etc.) and remove any obstructions. Inspect / replace gas pressure regulation system
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
E 607 HMax. number of fault resets reached
Truma's checks, in order: Wait 15 minutes and reset fault
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
E 621 HRoom temperature sensor or cable faulty
Truma's checks, in order: Inspect the room temperature sensor cable, replace if faulty
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
E 624 HFrostControl heating element has a short circuit
Truma's checks, in order: Disconnect heating element plug from electronic control unit. Replace heating element
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
E 632 HOverheating protection has been triggered
Truma's checks, in order: Reset overheating protection (see Combi operating instructions)
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
Green LED flashing fastNot a fault: after-run fan cooling the heater after switch-off.
Likely cause: Normal after-run (up to 5 minutes).
Truma's checks, in order: No action needed; it stops by itself.
Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 8. Open the document
Red LED x1-8Internal heater fault.
Likely cause: Fault inside the heater electronics or burner system.
Truma's checks, in order: Contact Truma service; the red LED on the heater electronics gives the detailed short/long flash code.
Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 8. Open the document
W 17 HSummer mode with empty water container
Truma's checks, in order: Switch heater off and allow it to cool. Fill boiler with water
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
W 18 HWarm air temperature exceeded: not all warm air ducts are connected; warm air outlets blocked; circulated air intake blocked
Truma's checks, in order: Check whether the 4 warm air ducts are connected. Check the individual outlet openings. Remove the circulated air intake blockage
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
W 21 HRoom temperature sensor or cable faulty
Truma's checks, in order: Inspect the room temperature sensor cable, replace if faulty. Check the resistance of the room temperature sensor: 15 °C – 16.2 kOhm / 20 °C – 12.6 kOhm / 25 °C – 10.0 kOhm. Replace room temperature sensor if faulty
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
W 24 HRisk of low voltage. Battery voltage is too low < 10.4 V
Truma's checks, in order: Charge battery
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
W 29 HFrostControl heating element has a short circuit
Truma's checks, in order: Disconnect heating element plug from electronic control unit. Replace heating element
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
W 42 HWindow above cowl open (window switch)
Truma's checks, in order: Close window
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
W 43 HOvervoltage > 16.4 V
Truma's checks, in order: Check battery voltage / voltage sources such as the charger
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
W 44 HLow voltage. Battery voltage is too low < 10.0 V
Truma's checks, in order: Charge battery. If necessary replace old battery
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
W 45 HNo 230 V operating voltage; 230 V fuse defective; overheating protection has been triggered
Truma's checks, in order: Restore 230 V operating voltage. Replace 230 V fuse (see Combi operating instructions). Reset overheating protection (see Combi operating instructions)
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
W 255 HHeater has no 12 V power supply; no connection between heater and control panel
Truma's checks, in order: Ensure that the 12 V power supply is available. Make connection between heater and control panel
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
W 301 HOvervoltage > 16.4 V
Truma's checks, in order: Check battery voltage / voltage sources such as the charger
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
W 302 HLow voltage. Battery voltage is too low < 10.0 V
Truma's checks, in order: Charge battery. If necessary replace old battery
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
W 303 HRisk of low voltage. Battery voltage is too low < 10.4 V
Truma's checks, in order: Charge battery
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
W 401 HSummer mode with empty water container
Truma's checks, in order: Switch heater off and allow it to cool. Fill boiler with water
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
W 402 HWarm air temperature exceeded: not all warm air ducts are connected; warm air outlets blocked; circulated air intake blocked
Truma's checks, in order: Check whether the 4 warm air ducts are connected. Check the individual outlet openings. Remove the circulated air intake blockage
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
W 407 HNo 230 V operating voltage; 230 V fuse defective
Truma's checks, in order: Restore 230 V operating voltage. Replace 230 V fuse (see Combi operating instructions)
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
W 408 HGASNo gas supply in Mix mode
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Truma's checks, in order: Check gas supply. See fault # 507 (electronic heating continues in Mix mode)
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
W 411 HRisk of low voltage. Battery voltage is too low < 10.4 V
Truma's checks, in order: Charge battery
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
W 412 HWindow above cowl open (window switch)
Truma's checks, in order: Close window
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
W 417 HOvervoltage > 16.4 V
Truma's checks, in order: Check battery voltage / voltage sources such as the charger
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
W 418 HLow voltage. Battery voltage is too low < 10.0 V
Truma's checks, in order: Charge battery. If necessary replace old battery
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
Yellow LED x1Battery voltage getting low (below 10.4 V); heater keeps running.
Likely cause: Leisure battery discharged or ageing.
Truma's checks, in order: Charge the battery.
Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 7. Open the document
Yellow LED x2Heater stopped: voltage too low (below 10.0 V) or too high (above 16.4 V); Combi E also no 230 V.
Likely cause: Flat/old battery, faulty charger, or on Combi E: no mains, blown 230 V fuse, overheat cut-out tripped.
Truma's checks, in order: Charge or replace battery, check charger; Combi E: restore 230 V, replace 230 V fuse or reset overheat button.
Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 7. Open the document
Yellow LED x3Window above the flue cowl is open (window switch).
Likely cause: Window over the cowl open, or window switch/cable faulty.
Truma's checks, in order: Close the window; if it is closed, check the window switch.
Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 7. Open the document
Yellow LED x4Overheating shutdown after running a while.
Likely cause: Summer mode with empty water tank, blocked warm-air outlets or blocked return-air intake.
Truma's checks, in order: Switch off and let cool; fill boiler with water; clear outlets and intake.
Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 8. Open the document
Yellow LED x5Room temperature sensor or its cable faulty.
Likely cause: Damaged sensor, broken or unplugged sensor cable.
Truma's checks, in order: Contact a Truma service agent to test sensor and cable.
Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 8. Open the document
Yellow LED x7Control panel or control panel cable faulty.
Likely cause: Damaged panel, loose or broken panel cable.
Truma's checks, in order: Contact a Truma service agent; check panel cable plugs.
Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 8. Open the document
Yellow LED x8FrostControl drain-valve heating element has short-circuited.
Likely cause: Faulty FrostControl heating element.
Truma's checks, in order: Unplug the heating element from the electronics and replace the element.
Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 8. Open the document
Yellow LED x9GASNo gas flame: gas supply problem.
Likely cause: Cylinder empty or valve closed, regulator iced up, or too much butane in cold weather.
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Truma's checks, in order: Open/replace the cylinder, fit a regulator heater (EisEx), use propane.
Source: Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guides, page 8. Open the document
Documents for the Combi 4 E4 documents from Truma
- Truma Combi (E) operating instructions - Combi 2 E UK, Combi 4 (E), Combi 6 (E) (Truma 34020-00851, rev 01, 02/2024, DE/EN/FR/IT/NL/DA/ES/SV)Manual · released Feb 2024 · Open it
- Truma CP (E) classic control panel - operating instructions (34030-11900, rev 02, 08/2013), incl. Combi gas and Combi diesel flash-code guidesManual · released Aug 2013 · Open it
- Truma CP plus operating instructions — troubleshooting guidesManual · Open it
- Truma Dealer Catalog 2025Catalogue · released 2025
Where these numbers come from
We don't invent part numbers. Every number on this page is copied from Truma's documents listed above, with the page. If a document is in doubt we hold the part back and say so.
Not sure it's an Combi 4 E?
The model number is on a rating plate or sticker on the appliance itself, not in the caravan paperwork.
How to read the plate All Truma modelsAll 78 parts for the Combi 4 E
Every part Truma's documents list for the Combi 4 E, grouped by area. Tap a part for its price, where to buy it and the page it came from.
Prices last seen between 14 Aug 2026 and 3 Nov 2026. Each price shows its own date. The shop's own page is final.
Seals & doors1 part
-
Truma Dealer Catalog 2025, page 25
$109.00 last in stock · last seen 16 Sep
Compare 4 shops
Electrical18 parts
-
New window switch, narrow, cpl.
Truma Dealer Catalog 2025, page 25
No Australian stockist yet
-
New wall cowl conversion kit combi d (e)Kit
Truma Dealer Catalog 2025, page 25
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 23
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 23
No Australian stockist yet
-
Cowl outer part zr 80, light grey
Truma Dealer Catalog 2025, page 23
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 23
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 41
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 23
$12.95 last in stock · last seen 29 Oct
Compare 2 shops -
Truma Dealer Catalog 2025, page 42
No Australian stockist yet
-
Cord-operated duct shut-off sp 2, agate grey
Truma Dealer Catalog 2025, page 43
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 42
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 39
$15.00 last in stock at 2 shops · last seen 27 Oct
Compare 2 shops -
Clamp üs 5, grey, ø 72 – 75 mm
Truma Dealer Catalog 2025, page 28
None in stock 2 shops list it · last seen 27 Oct
Compare 2 shops -
Truma Dealer Catalog 2025, page 44
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 44
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 44
No Australian stockist yet
-
Inet x room temperature sensor
Truma Dealer Catalog 2025, page 25
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 25
No Australian stockist yet
Covers & fittings10 parts
-
Straight coupling kit + grille insertKit
Truma Dealer Catalog 2025, page 43
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 43
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 25
None in stock 2 shops list it · last seen 29 Oct
Compare 2 shops -
Truma Dealer Catalog 2025, page 42
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 44
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 42
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 42
$14.95 last in stock at 3 shops · last seen 29 Oct
Compare 3 shops -
Truma Dealer Catalog 2025, page 44
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 44
No Australian stockist yet
-
Wall outlet vent wl, agate grey
Truma Dealer Catalog 2025, page 43
No Australian stockist yet
Other parts49 parts
-
Truma Dealer Catalog 2025, page 23
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 23
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 23
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 25
$40.00 last in stock at 2 shops · last seen 29 Oct
Compare 2 shops -
Truma Dealer Catalog 2025, page 23
$33.00 last in stock · last seen 27 Oct
Compare 2 shops -
Truma Dealer Catalog 2025, page 23
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 23
No Australian stockist yet
-
Cowl outer part zr 80, anthracite
Truma Dealer Catalog 2025, page 23
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 44
No Australian stockist yet
-
Air supply duct zr 18, ø 49 mm
Truma Dealer Catalog 2025, page 41
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 23
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 40
$52.95 last in stock · last seen 14 Aug
Where to buy -
Truma Dealer Catalog 2025, page 40
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 41
No Australian stockist yet
-
Air supply duct zr 80, ø 80 mm
Truma Dealer Catalog 2025, page 23
No Australian stockist yet
-
Swivel air outlet scw 2, black
Truma Dealer Catalog 2025, page 43
$45.95 last in stock at 7 shops · last seen 3 Nov
Compare 11 shops -
Swivel air outlet scw 2, beige
Truma Dealer Catalog 2025, page 43
No Australian stockist yet
-
Swivel air outlet scw 2, basalt grey
Truma Dealer Catalog 2025, page 43
No Australian stockist yet
-
Cord op. duct shut-off sp, agate grey
Truma Dealer Catalog 2025, page 43
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 43
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 43
None in stock 1 shop lists it · last seen 16 Sep
Where to buy -
Truma Dealer Catalog 2025, page 42
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 42
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 42
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 42
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 42
$13.28 last in stock at 8 shops · last seen 27 Oct
Compare 8 shops -
Truma Dealer Catalog 2025, page 42
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 42
$17.95 last in stock · last seen 29 Oct
Where to buy -
Truma Dealer Catalog 2025, page 42
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 42
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 42
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 43
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 41
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 30
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 44
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 44
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 44
No Australian stockist yet
-
Duct ir, ø 35 mm, without holes
Truma Dealer Catalog 2025, page 44
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 41
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 44
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 41
No Australian stockist yet
-
Lamellar insert la, agate grey
Truma Dealer Catalog 2025, page 42
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 42
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 42
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 42
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 42
$12.95 last in stock at 3 shops · last seen 29 Oct
Compare 6 shops -
Lamellar insert la, olive brown
Truma Dealer Catalog 2025, page 42
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 43
No Australian stockist yet
-
Truma Dealer Catalog 2025, page 43
$29.95 last in stock at 6 shops · last seen 29 Oct
Compare 6 shops
What the fit words mean
- Very likely fits 78 parts. From the maker's documents for this model, with a condition or a caveat we explain on the part.
Why 10 parts here aren't marked "Fits": Truma's dealer catalogue lists this as a fitting part for the Combi range. Gas Combi only. Page 14 states the ZR 80 wall cowl is shared with Combi D, but only the black and anthracite cowl outer parts are heat-resistant enough for a diesel Combi. Check it against the part you are replacing — the catalogue states fitment by family, not by individual model.
Why 6 parts here aren't marked "Fits": Truma's dealer catalogue lists this as a fitting part for the Combi range. Two rows are narrower than the heading: the blank cover CB is gas-Combi only, and the wall cowl conversion kit is Combi D only. Check it against the part you are replacing — the catalogue states fitment by family, not by individual model.
Why 39 parts here aren't marked "Fits": Truma's dealer catalogue lists this as a fitting part for the Combi range. Genuinely cross-model, but match on duct diameter rather than appliance. Several rows are narrower than the heading. Check it against the part you are replacing — the catalogue states fitment by family, not by individual model.
Why 13 parts here aren't marked "Fits": Truma's dealer catalogue lists this as a fitting part for the Combi range. Genuinely cross-model, but match on duct diameter rather than appliance. Several rows are narrower than the heading. Ducting is Ø65 throughout. Check it against the part you are replacing — the catalogue states fitment by family, not by individual model.
Parts shared across a range are often named after the first model they were made for, so a name may mention a different model. That doesn't mean it won't fit yours.
Is this my hot water system?
Check the plate on your hot water system says Combi 4 E.
- MOD. NO.
- Combi 4 E
- Item or product code
- 33714-20
The model number is on a rating plate or sticker on the appliance itself, not in the caravan paperwork.
Where's the plate on a Truma heater?
Not your model? See all Truma models or ask us to find it.