SparePartsMatcher

Truma hot water system

Truma Combi gas heater - CP plus / iNet X error codes (H = heater)

All 34 codes, what each one means and what to check, from Truma CP plus control panel - operating instructions (34020-00809, rev 00, 05/2019), Combi gas / diesel troubleshooting guides.

W 17 HSummer mode run with an empty water tank.

Likely cause: Summer mode with empty water container

Truma's checks, in order: Switch heater off and allow it to cool. Fill boiler with water

Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document

W 18 HWarm-air temperature too high.

Likely cause: Warm air temperature exceeded: not all warm air ducts are connected; warm air outlets blocked; circulated air intake blocked

Truma's checks, in order: Check whether the 4 warm air ducts are connected. Check the individual outlet openings. Remove the circulated air intake blockage

Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document

W 21 HRoom temperature sensor or cable faulty (warning).

Likely cause: Room temperature sensor or cable faulty

Truma's checks, in order: Inspect the room temperature sensor cable, replace if faulty. Check the resistance of the room temperature sensor: 15 °C – 16.2 kOhm / 20 °C – 12.6 kOhm / 25 °C – 10.0 kOhm. Replace room temperature sensor if faulty

Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document

W 24 HBattery voltage getting low (below 10.4 V).

Likely cause: Risk of low voltage. Battery voltage is too low < 10.4 V

Truma's checks, in order: Charge battery

Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document

W 29 HFrostControl heating element short circuit (warning).

Likely cause: FrostControl heating element has a short circuit

Truma's checks, in order: Disconnect heating element plug from electronic control unit. Replace heating element

Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document

W 42 HWindow above the cowl open (window switch).

Likely cause: Window above cowl open (window switch)

Truma's checks, in order: Close window

Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document

W 43 HVoltage too high (above 16.4 V).

Likely cause: Overvoltage > 16.4 V

Truma's checks, in order: Check battery voltage / voltage sources such as the charger

Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document

W 44 HVoltage too low (below 10.0 V).

Likely cause: Low voltage. Battery voltage is too low < 10.0 V

Truma's checks, in order: Charge battery. If necessary replace old battery

Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document

W 45 HNo 230 V for electric heating (E models).

Likely cause: No 230 V operating voltage; 230 V fuse defective; overheating protection has been triggered

Truma's checks, in order: Restore 230 V operating voltage. Replace 230 V fuse (see Combi operating instructions). Reset overheating protection (see Combi operating instructions)

Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document

E 112 HGASGas burner fault: no flame.

Likely cause: Gas cylinder empty

Gas fault: get a licensed gas fitter

Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.

Truma's checks, in order: Replace the gas cylinder

Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document

E 121 HGASGas burner fault: no flame (gas supply).

Likely cause: Gas cylinder or quick-acting valve in the gas supply line

Gas fault: get a licensed gas fitter

Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.

Truma's checks, in order: Check gas supply and open valves

Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document

E 122 HGASGas burner fault: no flame (gas supply).

Likely cause: Gas pressure regulation system iced up

Gas fault: get a licensed gas fitter

Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.

Truma's checks, in order: Use regulator heater (EisEx)

Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document

E 202 HGASGas burner fault: no flame (gas supply).

Likely cause: Butane content in the gas cylinder too high

Gas fault: get a licensed gas fitter

Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.

Truma's checks, in order: Use propane. Butane is unsuitable for heating, particularly at temperatures below 10 °C

Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document

E 211 HGASGas burner fault: no flame (gas supply).

Likely cause: Combustion air infeed or exhaust outlet is sealed

Gas fault: get a licensed gas fitter

Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.

Truma's checks, in order: Inspect openings for obstructions (slush, ice, leaves, etc.) and remove any obstructions

Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document

E 212 HGASGas burner fault: no flame (gas supply).

Likely cause: Gas pressure regulation system faulty

Gas fault: get a licensed gas fitter

Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.

Truma's checks, in order: Inspect / replace gas pressure regulation system

Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document

W 255 HHeater not talking to the panel.

Likely cause: Heater has no 12 V power supply; no connection between heater and control panel

Truma's checks, in order: Ensure that the 12 V power supply is available. Make connection between heater and control panel

Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document

W 301 HVoltage too high (above 16.4 V).

Likely cause: Overvoltage > 16.4 V

Truma's checks, in order: Check battery voltage / voltage sources such as the charger

Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document

W 417 HVoltage too high (above 16.4 V).

Likely cause: Overvoltage > 16.4 V

Truma's checks, in order: Check battery voltage / voltage sources such as the charger

Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document

W 302 HVoltage too low (below 10.0 V).

Likely cause: Low voltage. Battery voltage is too low < 10.0 V

Truma's checks, in order: Charge battery. If necessary replace old battery

Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document

W 418 HVoltage too low (below 10.0 V).

Likely cause: Low voltage. Battery voltage is too low < 10.0 V

Truma's checks, in order: Charge battery. If necessary replace old battery

Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document

W 303 HBattery voltage getting low (below 10.4 V).

Likely cause: Risk of low voltage. Battery voltage is too low < 10.4 V

Truma's checks, in order: Charge battery

Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document

W 411 HBattery voltage getting low (below 10.4 V).

Likely cause: Risk of low voltage. Battery voltage is too low < 10.4 V

Truma's checks, in order: Charge battery

Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document

W 401 HSummer mode run with an empty water tank.

Likely cause: Summer mode with empty water container

Truma's checks, in order: Switch heater off and allow it to cool. Fill boiler with water

Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document

W 402 HWarm-air temperature too high.

Likely cause: Warm air temperature exceeded: not all warm air ducts are connected; warm air outlets blocked; circulated air intake blocked

Truma's checks, in order: Check whether the 4 warm air ducts are connected. Check the individual outlet openings. Remove the circulated air intake blockage

Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document

W 407 HNo 230 V for electric heating.

Likely cause: No 230 V operating voltage; 230 V fuse defective

Truma's checks, in order: Restore 230 V operating voltage. Replace 230 V fuse (see Combi operating instructions)

Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document

W 408 HGASNo gas while in Mix mode; electric heating continues.

Likely cause: No gas supply in Mix mode

Gas fault: get a licensed gas fitter

Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.

Truma's checks, in order: Check gas supply. See fault # 507 (electronic heating continues in Mix mode)

Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document

W 412 HWindow above the cowl open (window switch).

Likely cause: Window above cowl open (window switch)

Truma's checks, in order: Close window

Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document

E 507 HGASGas burner fault: cylinder empty.

Likely cause: Gas cylinder empty

Gas fault: get a licensed gas fitter

Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.

Truma's checks, in order: Replace the gas cylinder

Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document

E 516 HGASGas burner fault: no flame (gas supply).

Likely cause: Gas cylinder or quick-acting valve in the gas supply line closed

Gas fault: get a licensed gas fitter

Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.

Truma's checks, in order: Check gas supply and open valves

Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document

E 517 HGASGas burner fault: no flame (gas supply).

Likely cause: Gas pressure regulation system iced up; butane content in the gas cylinder too high; combustion air infeed or exhaust outlet is sealed; gas pressure regulation system faulty

Gas fault: get a licensed gas fitter

Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.

Truma's checks, in order: Use regulator heater (EisEx). Use propane — butane is unsuitable for heating, particularly at temperatures below 10 °C. Inspect openings for obstructions (slush, ice, leaves, etc.) and remove any obstructions. Inspect / replace gas pressure regulation system

Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document

E 607 HToo many fault resets in a row; reset blocked.

Likely cause: Max. number of fault resets reached

Truma's checks, in order: Wait 15 minutes and reset fault

Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document

E 621 HRoom temperature sensor or cable faulty.

Likely cause: Room temperature sensor or cable faulty

Truma's checks, in order: Inspect the room temperature sensor cable, replace if faulty

Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document

E 624 HFrostControl heating element short circuit.

Likely cause: FrostControl heating element has a short circuit

Truma's checks, in order: Disconnect heating element plug from electronic control unit. Replace heating element

Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document

E 632 HOverheat protection triggered.

Likely cause: Overheating protection has been triggered

Truma's checks, in order: Reset overheating protection (see Combi operating instructions)

Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document

Where this comes from

Truma CP plus control panel - operating instructions (34020-00809, rev 00, 05/2019), Combi gas / diesel troubleshooting guides, published by Truma. Open the PDF

We don't invent fault codes or part numbers. Each code above carries the page it came from.