Truma hot water system
Truma Combi gas heater - CP plus / iNet X error codes (H = heater)
All 34 codes, what each one means and what to check, from Truma CP plus control panel - operating instructions (34020-00809, rev 00, 05/2019), Combi gas / diesel troubleshooting guides.
W 17 HSummer mode run with an empty water tank.
Likely cause: Summer mode with empty water container
Truma's checks, in order: Switch heater off and allow it to cool. Fill boiler with water
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
W 18 HWarm-air temperature too high.
Likely cause: Warm air temperature exceeded: not all warm air ducts are connected; warm air outlets blocked; circulated air intake blocked
Truma's checks, in order: Check whether the 4 warm air ducts are connected. Check the individual outlet openings. Remove the circulated air intake blockage
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
W 21 HRoom temperature sensor or cable faulty (warning).
Likely cause: Room temperature sensor or cable faulty
Truma's checks, in order: Inspect the room temperature sensor cable, replace if faulty. Check the resistance of the room temperature sensor: 15 °C – 16.2 kOhm / 20 °C – 12.6 kOhm / 25 °C – 10.0 kOhm. Replace room temperature sensor if faulty
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
W 24 HBattery voltage getting low (below 10.4 V).
Likely cause: Risk of low voltage. Battery voltage is too low < 10.4 V
Truma's checks, in order: Charge battery
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
W 29 HFrostControl heating element short circuit (warning).
Likely cause: FrostControl heating element has a short circuit
Truma's checks, in order: Disconnect heating element plug from electronic control unit. Replace heating element
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
W 42 HWindow above the cowl open (window switch).
Likely cause: Window above cowl open (window switch)
Truma's checks, in order: Close window
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
W 43 HVoltage too high (above 16.4 V).
Likely cause: Overvoltage > 16.4 V
Truma's checks, in order: Check battery voltage / voltage sources such as the charger
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
W 44 HVoltage too low (below 10.0 V).
Likely cause: Low voltage. Battery voltage is too low < 10.0 V
Truma's checks, in order: Charge battery. If necessary replace old battery
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
W 45 HNo 230 V for electric heating (E models).
Likely cause: No 230 V operating voltage; 230 V fuse defective; overheating protection has been triggered
Truma's checks, in order: Restore 230 V operating voltage. Replace 230 V fuse (see Combi operating instructions). Reset overheating protection (see Combi operating instructions)
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
E 112 HGASGas burner fault: no flame.
Likely cause: Gas cylinder empty
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Truma's checks, in order: Replace the gas cylinder
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
E 121 HGASGas burner fault: no flame (gas supply).
Likely cause: Gas cylinder or quick-acting valve in the gas supply line
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Truma's checks, in order: Check gas supply and open valves
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
E 122 HGASGas burner fault: no flame (gas supply).
Likely cause: Gas pressure regulation system iced up
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Truma's checks, in order: Use regulator heater (EisEx)
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
E 202 HGASGas burner fault: no flame (gas supply).
Likely cause: Butane content in the gas cylinder too high
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Truma's checks, in order: Use propane. Butane is unsuitable for heating, particularly at temperatures below 10 °C
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
E 211 HGASGas burner fault: no flame (gas supply).
Likely cause: Combustion air infeed or exhaust outlet is sealed
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Truma's checks, in order: Inspect openings for obstructions (slush, ice, leaves, etc.) and remove any obstructions
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
E 212 HGASGas burner fault: no flame (gas supply).
Likely cause: Gas pressure regulation system faulty
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Truma's checks, in order: Inspect / replace gas pressure regulation system
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
W 255 HHeater not talking to the panel.
Likely cause: Heater has no 12 V power supply; no connection between heater and control panel
Truma's checks, in order: Ensure that the 12 V power supply is available. Make connection between heater and control panel
Source: Truma CP plus operating instructions — troubleshooting guides, page 17. Open the document
W 301 HVoltage too high (above 16.4 V).
Likely cause: Overvoltage > 16.4 V
Truma's checks, in order: Check battery voltage / voltage sources such as the charger
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
W 417 HVoltage too high (above 16.4 V).
Likely cause: Overvoltage > 16.4 V
Truma's checks, in order: Check battery voltage / voltage sources such as the charger
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
W 302 HVoltage too low (below 10.0 V).
Likely cause: Low voltage. Battery voltage is too low < 10.0 V
Truma's checks, in order: Charge battery. If necessary replace old battery
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
W 418 HVoltage too low (below 10.0 V).
Likely cause: Low voltage. Battery voltage is too low < 10.0 V
Truma's checks, in order: Charge battery. If necessary replace old battery
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
W 303 HBattery voltage getting low (below 10.4 V).
Likely cause: Risk of low voltage. Battery voltage is too low < 10.4 V
Truma's checks, in order: Charge battery
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
W 411 HBattery voltage getting low (below 10.4 V).
Likely cause: Risk of low voltage. Battery voltage is too low < 10.4 V
Truma's checks, in order: Charge battery
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
W 401 HSummer mode run with an empty water tank.
Likely cause: Summer mode with empty water container
Truma's checks, in order: Switch heater off and allow it to cool. Fill boiler with water
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
W 402 HWarm-air temperature too high.
Likely cause: Warm air temperature exceeded: not all warm air ducts are connected; warm air outlets blocked; circulated air intake blocked
Truma's checks, in order: Check whether the 4 warm air ducts are connected. Check the individual outlet openings. Remove the circulated air intake blockage
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
W 407 HNo 230 V for electric heating.
Likely cause: No 230 V operating voltage; 230 V fuse defective
Truma's checks, in order: Restore 230 V operating voltage. Replace 230 V fuse (see Combi operating instructions)
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
W 408 HGASNo gas while in Mix mode; electric heating continues.
Likely cause: No gas supply in Mix mode
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Truma's checks, in order: Check gas supply. See fault # 507 (electronic heating continues in Mix mode)
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
W 412 HWindow above the cowl open (window switch).
Likely cause: Window above cowl open (window switch)
Truma's checks, in order: Close window
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
E 507 HGASGas burner fault: cylinder empty.
Likely cause: Gas cylinder empty
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Truma's checks, in order: Replace the gas cylinder
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
E 516 HGASGas burner fault: no flame (gas supply).
Likely cause: Gas cylinder or quick-acting valve in the gas supply line closed
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Truma's checks, in order: Check gas supply and open valves
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
E 517 HGASGas burner fault: no flame (gas supply).
Likely cause: Gas pressure regulation system iced up; butane content in the gas cylinder too high; combustion air infeed or exhaust outlet is sealed; gas pressure regulation system faulty
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Truma's checks, in order: Use regulator heater (EisEx). Use propane — butane is unsuitable for heating, particularly at temperatures below 10 °C. Inspect openings for obstructions (slush, ice, leaves, etc.) and remove any obstructions. Inspect / replace gas pressure regulation system
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
E 607 HToo many fault resets in a row; reset blocked.
Likely cause: Max. number of fault resets reached
Truma's checks, in order: Wait 15 minutes and reset fault
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
E 621 HRoom temperature sensor or cable faulty.
Likely cause: Room temperature sensor or cable faulty
Truma's checks, in order: Inspect the room temperature sensor cable, replace if faulty
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
E 624 HFrostControl heating element short circuit.
Likely cause: FrostControl heating element has a short circuit
Truma's checks, in order: Disconnect heating element plug from electronic control unit. Replace heating element
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
E 632 HOverheat protection triggered.
Likely cause: Overheating protection has been triggered
Truma's checks, in order: Reset overheating protection (see Combi operating instructions)
Source: Truma CP plus operating instructions — troubleshooting guides, page 18. Open the document
Where this comes from
Truma CP plus control panel - operating instructions (34020-00809, rev 00, 05/2019), Combi gas / diesel troubleshooting guides, published by Truma. Open the PDF
We don't invent fault codes or part numbers. Each code above carries the page it came from.