Autoterm hot water system

Autoterm FLOW-5D hot water system fault codes

25 fault codes from Autoterm's own manual. We hold no spare parts list for this model yet.

We have no spare parts list for the FLOW-5D yet. The moment we get Autoterm's list, the parts appear here.

Tell us which part you're after

A code on the display?

25 fault codes for the FLOW-5D, from Autoterm's own documents. Tap one to see what to check.

01Overheating (upper temperature limit exceeded)

Likely cause: Temperature near a sensor exceeds 120°C

Autoterm's checks, in order: Check liquid circuit for air blocks; check pump; check overheating and temperature sensors; check antifreeze suitability

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 5.

03Temperature sensor 1 fault

Likely cause: Short or open circuit in wiring

Autoterm's checks, in order: Replace the sensor assembly

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 5.

04Temperature sensor 2 fault

Likely cause: Short or open circuit in wiring

Autoterm's checks, in order: Replace the sensor assembly

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 5.

05GASFlame detector fault

Likely cause: Short to frame or open circuit in detector wiring

Gas fault: get a licensed gas fitter

Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.

Autoterm's checks, in order: Check the flame detector

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 5.

06Control unit temperature sensor fault

Likely cause: Sensor inside control unit faulty; not separately replaceable

Autoterm's checks, in order: Replace the control unit

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 5.

09Glow plug fault

Likely cause: Short or open circuit, or control unit fault

Autoterm's checks, in order: Check glow plug; check control unit

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 5.

Show all 25 codes

10Air blower speed lower than rated

Likely cause: Foreign particles obstructing the spinner, or spinner fouling the cover

Autoterm's checks, in order: Check wiring; check air blower for dirt

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 5.

12Shutdown due to overvoltage

Likely cause: Supply voltage above 16 V

Autoterm's checks, in order: Check voltage at XS2, fuses, battery, regulator, supply wiring

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 5.

13All start attempts failed

Likely cause: Failure to ignite after two attempts

Autoterm's checks, in order: Check fuel line, fuel pump, air blower, exhaust, combustion chamber; clean plug nozzle

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 5.

14Pump fault

Likely cause: Short or open circuit in current-carrying parts

Autoterm's checks, in order: Check pump wiring; clean pumping elements

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 5.

15Shutdown due to undervoltage

Likely cause: Supply voltage below 10 V

Autoterm's checks, in order: Check voltage at XS2, fuses, battery, regulator, supply wiring

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.

16Ventilation time exceeded

Likely cause: Flame detector not sufficiently cooled by purging

Autoterm's checks, in order: Check air intake and exhaust; check or replace flame detector

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.

17Fuel pump short circuit

Likely cause: Short circuit in fuel pump wiring

Autoterm's checks, in order: Check the fuel pump

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.

20No communication between control unit and panel

Likely cause: Short or open circuit in wiring to panel

Autoterm's checks, in order: Check 5 A fuse; check circuits and terminals

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.

21GASFlame blowoff in WARMUP mode

Likely cause: Poor combustion, fouled heat exchanger, or clogged exhaust

Gas fault: get a licensed gas fitter

Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.

Autoterm's checks, in order: Check air intake, exhaust, fuel supply; replace fuel pump or flame detector if needed

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.

22Fuel pump open circuit

Likely cause: Open circuit in fuel pump wiring

Autoterm's checks, in order: Check the fuel pump

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.

24Rapid temperature change at one sensor

Likely cause: Possible overheating from poor coolant circulation

Autoterm's checks, in order: Check circuit for air blocks; check pump; check sensors; check antifreeze

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.

25Coolant heated too quickly

Likely cause: Entered cooling-down mode 3+ times within 6 minutes

Autoterm's checks, in order: As per code 24

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.

27Air blower fault — motor not rotating

Likely cause: Mechanical obstruction

Autoterm's checks, in order: Check air blower for obstruction

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.

28Air blower fault — uncontrolled rotation

Likely cause: Possible 5 V supply fault to control unit

Autoterm's checks, in order: Check wiring, air blower and control unit

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.

29GASAll ignition attempts failed in operation

Likely cause: Ignition attempted more than four times

Gas fault: get a licensed gas fitter

Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.

Autoterm's checks, in order: Check fuel line clamps and seal, fuel pump nozzle seal, pump capacity

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.

30GASFlame blowoff from voltage drop

Likely cause: Air blower stops when vehicle voltage drops

Gas fault: get a licensed gas fitter

Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.

Autoterm's checks, in order: Check battery and wiring; may follow long starter operation

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.

37Pre-heater locked

Likely cause: Malfunction 13 occurred three times consecutively

Autoterm's checks, in order: Eliminate the cause, then unlock the pre-heater

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.

50No communication between panel and router

Likely cause: Short or open circuit in wiring

Autoterm's checks, in order: Check 5 A fuse; check circuits and terminals

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.

78GASFlame blowoff (informational)

Likely cause: Flame blowoff during operation; warning, not critical

Gas fault: get a licensed gas fitter

Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.

Autoterm's checks, in order: Check fuel line clamps, fuel line seal, fuel pump nozzle seal

Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.

Documents for the FLOW-5D1 document from Autoterm
  • FLOW-5B / FLOW-5D repair manual v11.2017Troubleshooting guide · released Nov 2017
Where these numbers come from

We don't invent part numbers. Every number on this page is copied from Autoterm's documents listed above, with the page. If a document is in doubt we hold the part back and say so.

How we check a part fits

Not sure it's an FLOW-5D?

On a hot water system it's on the body of the unit behind the outside service door.

How to read the plate All Autoterm models

Is this my hot water system?

Check the plate on your hot water system says FLOW-5D.

MOD. NO.
FLOW-5D

On a hot water system it's on the body of the unit behind the outside service door.

Where's the plate on a Autoterm heater?

Not your model? See all Autoterm models or ask us to find it.

Yes, show my parts