Autoterm hot water system
Autoterm FLOW-5D hot water system fault codes
25 fault codes from Autoterm's own manual. We hold no spare parts list for this model yet.
We have no spare parts list for the FLOW-5D yet. The moment we get Autoterm's list, the parts appear here.
Tell us which part you're afterA code on the display?
25 fault codes for the FLOW-5D, from Autoterm's own documents. Tap one to see what to check.
01Overheating (upper temperature limit exceeded)
Likely cause: Temperature near a sensor exceeds 120°C
Autoterm's checks, in order: Check liquid circuit for air blocks; check pump; check overheating and temperature sensors; check antifreeze suitability
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 5.
03Temperature sensor 1 fault
Likely cause: Short or open circuit in wiring
Autoterm's checks, in order: Replace the sensor assembly
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 5.
04Temperature sensor 2 fault
Likely cause: Short or open circuit in wiring
Autoterm's checks, in order: Replace the sensor assembly
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 5.
05GASFlame detector fault
Likely cause: Short to frame or open circuit in detector wiring
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Autoterm's checks, in order: Check the flame detector
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 5.
06Control unit temperature sensor fault
Likely cause: Sensor inside control unit faulty; not separately replaceable
Autoterm's checks, in order: Replace the control unit
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 5.
09Glow plug fault
Likely cause: Short or open circuit, or control unit fault
Autoterm's checks, in order: Check glow plug; check control unit
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 5.
Show all 25 codes
10Air blower speed lower than rated
Likely cause: Foreign particles obstructing the spinner, or spinner fouling the cover
Autoterm's checks, in order: Check wiring; check air blower for dirt
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 5.
12Shutdown due to overvoltage
Likely cause: Supply voltage above 16 V
Autoterm's checks, in order: Check voltage at XS2, fuses, battery, regulator, supply wiring
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 5.
13All start attempts failed
Likely cause: Failure to ignite after two attempts
Autoterm's checks, in order: Check fuel line, fuel pump, air blower, exhaust, combustion chamber; clean plug nozzle
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 5.
14Pump fault
Likely cause: Short or open circuit in current-carrying parts
Autoterm's checks, in order: Check pump wiring; clean pumping elements
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 5.
15Shutdown due to undervoltage
Likely cause: Supply voltage below 10 V
Autoterm's checks, in order: Check voltage at XS2, fuses, battery, regulator, supply wiring
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.
16Ventilation time exceeded
Likely cause: Flame detector not sufficiently cooled by purging
Autoterm's checks, in order: Check air intake and exhaust; check or replace flame detector
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.
17Fuel pump short circuit
Likely cause: Short circuit in fuel pump wiring
Autoterm's checks, in order: Check the fuel pump
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.
20No communication between control unit and panel
Likely cause: Short or open circuit in wiring to panel
Autoterm's checks, in order: Check 5 A fuse; check circuits and terminals
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.
21GASFlame blowoff in WARMUP mode
Likely cause: Poor combustion, fouled heat exchanger, or clogged exhaust
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Autoterm's checks, in order: Check air intake, exhaust, fuel supply; replace fuel pump or flame detector if needed
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.
22Fuel pump open circuit
Likely cause: Open circuit in fuel pump wiring
Autoterm's checks, in order: Check the fuel pump
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.
24Rapid temperature change at one sensor
Likely cause: Possible overheating from poor coolant circulation
Autoterm's checks, in order: Check circuit for air blocks; check pump; check sensors; check antifreeze
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.
25Coolant heated too quickly
Likely cause: Entered cooling-down mode 3+ times within 6 minutes
Autoterm's checks, in order: As per code 24
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.
27Air blower fault — motor not rotating
Likely cause: Mechanical obstruction
Autoterm's checks, in order: Check air blower for obstruction
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.
28Air blower fault — uncontrolled rotation
Likely cause: Possible 5 V supply fault to control unit
Autoterm's checks, in order: Check wiring, air blower and control unit
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.
29GASAll ignition attempts failed in operation
Likely cause: Ignition attempted more than four times
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Autoterm's checks, in order: Check fuel line clamps and seal, fuel pump nozzle seal, pump capacity
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.
30GASFlame blowoff from voltage drop
Likely cause: Air blower stops when vehicle voltage drops
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Autoterm's checks, in order: Check battery and wiring; may follow long starter operation
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.
37Pre-heater locked
Likely cause: Malfunction 13 occurred three times consecutively
Autoterm's checks, in order: Eliminate the cause, then unlock the pre-heater
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.
50No communication between panel and router
Likely cause: Short or open circuit in wiring
Autoterm's checks, in order: Check 5 A fuse; check circuits and terminals
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.
78GASFlame blowoff (informational)
Likely cause: Flame blowoff during operation; warning, not critical
Gas fault: get a licensed gas fitter
Turn the gas off at the bottle and run the appliance on another power source until it's checked. Only a licensed gas fitter should work on the gas side.
Autoterm's checks, in order: Check fuel line clamps, fuel line seal, fuel pump nozzle seal
Source: FLOW-5B / FLOW-5D repair manual v11.2017, page 6.
Documents for the FLOW-5D1 document from Autoterm
- FLOW-5B / FLOW-5D repair manual v11.2017Troubleshooting guide · released Nov 2017
Where these numbers come from
We don't invent part numbers. Every number on this page is copied from Autoterm's documents listed above, with the page. If a document is in doubt we hold the part back and say so.
Not sure it's an FLOW-5D?
On a hot water system it's on the body of the unit behind the outside service door.
How to read the plate All Autoterm modelsIs this my hot water system?
Check the plate on your hot water system says FLOW-5D.
- MOD. NO.
- FLOW-5D
On a hot water system it's on the body of the unit behind the outside service door.
Where's the plate on a Autoterm heater?
Not your model? See all Autoterm models or ask us to find it.